Follow
Alfred Michael Franz
Alfred Michael Franz
University of Applied Sciences Ulm
Verified email at hs-ulm.de
Title
Cited by
Cited by
Year
Electromagnetic tracking in medicine—a review of technology, validation, and applications
AM Franz, T Haidegger, W Birkfellner, K Cleary, TM Peters, L Maier-Hein
IEEE transactions on medical imaging 33 (8), 1702-1725, 2014
4962014
The Medical Imaging Interaction Toolkit: challenges and advances: 10 years of open-source development
M Nolden, S Zelzer, A Seitel, D Wald, M Müller, AM Franz, D Maleike, ...
International journal of computer assisted radiology and surgery 8, 607-620, 2013
4542013
Convergent iterative closest-point algorithm to accomodate anisotropic and inhomogenous localization error
L Maier-Hein, AM Franz, TR Dos Santos, M Schmidt, M Fangerau, ...
IEEE transactions on pattern analysis and machine intelligence 34 (8), 1520-1532, 2011
1472011
In vivo accuracy assessment of a needle‐based navigation system for CT‐guided radiofrequency ablation of the liver
L Maier‐Hein, A Tekbas, A Seitel, F Pianka, SA Müller, S Satzl, S Schawo, ...
Medical physics 35 (12), 5385-5396, 2008
1082008
Standardized assessment of new electromagnetic field generators in an interventional radiology setting
L Maier‐Hein, AM Franz, W Birkfellner, J Hummel, I Gergel, I Wegner, ...
Medical physics 39 (6Part1), 3424-3434, 2012
832012
Towards mobile augmented reality for on-patient visualization of medical images
L Maier-Hein, AM Franz, M Fangerau, M Schmidt, A Seitel, S Mersmann, ...
Bildverarbeitung für die Medizin 2011: Algorithmen-Systeme-Anwendungen …, 2011
582011
Anser EMT: the first open-source electromagnetic tracking platform for image-guided interventions
HA Jaeger, AM Franz, K O’Donoghue, A Seitel, F Trauzettel, L Maier-Hein, ...
International journal of computer assisted radiology and surgery 12, 1059-1067, 2017
462017
Electromagnetic tracking for US-guided interventions: standardized assessment of a new compact field generator
AM Franz, K März, J Hummel, W Birkfellner, R Bendl, S Delorme, ...
International journal of computer assisted radiology and surgery 7, 813-818, 2012
412012
Accounting for anisotropic noise in fine registration of time-of-flight range data with high-resolution surface data
L Maier-Hein, M Schmidt, AM Franz, TR dos Santos, A Seitel, B Jähne, ...
Medical Image Computing and Computer-Assisted Intervention–MICCAI 2010: 13th …, 2010
402010
Standardized accuracy assessment of the calypso wireless transponder tracking system
AM Franz, D Schmitt, A Seitel, M Chatrasingh, G Echner, U Oelfke, S Nill, ...
Physics in Medicine & Biology 59 (22), 6797, 2014
342014
Towards markerless navigation for percutaneous needle insertions
A Seitel, N Bellemann, M Hafezi, AM Franz, M Servatius, A Saffari, ...
International journal of computer assisted radiology and surgery 11, 107-117, 2016
312016
On combining internal and external fiducials for liver motion compensation
L Maier-Hein, A Tekbas, AM Franz, R Tetzlaff, SA Müller, F Pianka, I Wolf, ...
Computer Aided Surgery 13 (6), 369-376, 2008
262008
MITK-US: real-time ultrasound support within MITK
K März, AM Franz, A Seitel, A Winterstein, R Bendl, S Zelzer, M Nolden, ...
International journal of computer assisted radiology and surgery 9, 411-420, 2014
222014
Respiratory liver motion simulator for validating image-guided systems ex-vivo
L Maier-Hein, F Pianka, SA Müller, U Rietdorf, A Seitel, AM Franz, I Wolf, ...
International Journal of Computer Assisted Radiology and Surgery 2, 287-292, 2008
212008
Simplified development of image-guided therapy software with MITK-IGT
AM Franz, A Seitel, M Servatius, C Zöllner, I Gergel, I Wegner, J Neuhaus, ...
Medical Imaging 2012: Image-Guided Procedures, Robotic Interventions, and …, 2012
202012
Comparative assessment of optical tracking systems for soft tissue navigation with fiducial needles
L Maier-Hein, A Franz, HP Meinzer, I Wolf
Medical Imaging 2008: Visualization, Image-Guided Procedures, and Modeling …, 2008
202008
Soft tissue navigation using needle-shaped markers: Evaluation of navigation aid tracking accuracy and CT registration
L Maier-Hein, D Maleike, J Neuhaus, A Franz, I Wolf, HP Meinzer
Medical Imaging 2007: Visualization and Image-Guided Procedures 6509, 758-769, 2007
202007
Navigated liver biopsy using a novel soft tissue navigation system versus CT-guided liver biopsy in a porcine model: a prospective randomized trial
SA Müller, L Maier-Hein, A Tekbas, A Seitel, S Ramsauer, B Radeleff, ...
Academic radiology 17 (10), 1282-1287, 2010
192010
Polhemus EM tracked Micro Sensor for CT‐guided interventions
AM Franz, A Seitel, D Cheray, L Maier‐Hein
Medical physics 46 (1), 15-24, 2019
182019
Interventional real-time ultrasound imaging with an integrated electromagnetic field generator
K März, AM Franz, A Seitel, A Winterstein, M Hafezi, A Saffari, R Bendl, ...
International journal of computer assisted radiology and surgery 9, 759-768, 2014
172014
The system can't perform the operation now. Try again later.
Articles 1–20