Folgen
Benedikt A Poser
Benedikt A Poser
Bestätigte E-Mail-Adresse bei maastrichtuniversity.nl
Titel
Zitiert von
Zitiert von
Jahr
Simultaneous multislice (SMS) imaging techniques
M Barth, F Breuer, PJ Koopmans, DG Norris, BA Poser
Magnetic resonance in medicine 75 (1), 63-81, 2016
6572016
BOLD contrast sensitivity enhancement and artifact reduction with multiecho EPI: parallel‐acquired inhomogeneity‐desensitized fMRI
BA Poser, MJ Versluis, JM Hoogduin, DG Norris
Magnetic Resonance in Medicine: An Official Journal of the International …, 2006
4742006
Three dimensional echo-planar imaging at 7 Tesla
BA Poser, PJ Koopmans, T Witzel, LL Wald, M Barth
Neuroimage 51 (1), 261-266, 2010
3472010
High-resolution CBV-fMRI allows mapping of laminar activity and connectivity of cortical input and output in human M1
L Huber, DA Handwerker, DC Jangraw, G Chen, A Hall, C Stüber, ...
Neuron 96 (6), 1253-1263. e7, 2017
3132017
Multi-echo fMRI: a review of applications in fMRI denoising and analysis of BOLD signals
P Kundu, V Voon, P Balchandani, MV Lombardo, BA Poser, PA Bandettini
Neuroimage 154, 59-80, 2017
3052017
Locus coeruleus imaging as a biomarker for noradrenergic dysfunction in neurodegenerative diseases
MJ Betts, E Kirilina, MCG Otaduy, D Ivanov, J Acosta-Cabronero, ...
Brain 142 (9), 2558-2571, 2019
2952019
Fast quantitative susceptibility mapping using 3D EPI and total generalized variation
C Langkammer, K Bredies, BA Poser, M Barth, G Reishofer, AP Fan, ...
Neuroimage 111, 622-630, 2015
2512015
RF excitation using time interleaved acquisition of modes (TIAMO) to address B1 inhomogeneity in high‐field MRI
S Orzada, S Maderwald, BA Poser, AK Bitz, HH Quick, ME Ladd
Magnetic resonance in medicine 64 (2), 327-333, 2010
1682010
Slab‐selective, BOLD‐corrected VASO at 7 Tesla provides measures of cerebral blood volume reactivity with high signal‐to‐noise ratio
L Huber, D Ivanov, SN Krieger, MN Streicher, T Mildner, BA Poser, ...
Magnetic resonance in medicine 72 (1), 137-148, 2014
1542014
Investigating the benefits of multi-echo EPI for fMRI at 7 T
BA Poser, DG Norris
Neuroimage 45 (4), 1162-1172, 2009
1522009
High-resolution in vivo imaging of human locus coeruleus by magnetization transfer MRI at 3T and 7T
N Priovoulos, HIL Jacobs, D Ivanov, K Uludağ, FRJ Verhey, BA Poser
Neuroimage 168, 427-436, 2018
1512018
Techniques for blood volume fMRI with VASO: From low-resolution mapping towards sub-millimeter layer-dependent applications
L Huber, D Ivanov, DA Handwerker, S Marrett, M Guidi, K Uludağ, ...
Neuroimage 164, 131-143, 2018
1252018
Layer-dependent functional connectivity methods
L Huber, ES Finn, Y Chai, R Goebel, R Stirnberg, T Stöcker, S Marrett, ...
Progress in Neurobiology 207, 101835, 2021
1092021
Sub-millimeter fMRI reveals multiple topographical digit representations that form action maps in human motor cortex
L Huber, ES Finn, DA Handwerker, M Bönstrup, DR Glen, S Kashyap, ...
Neuroimage 208, 116463, 2020
1042020
LayNii: A software suite for layer-fMRI
LR Huber, BA Poser, PA Bandettini, K Arora, K Wagstyl, S Cho, J Goense, ...
NeuroImage 237, 118091, 2021
1012021
Sub-millimeter T2 weighted fMRI at 7 T: comparison of 3D-GRASE and 2D SE-EPI
VG Kemper, F De Martino, AT Vu, BA Poser, DA Feinberg, R Goebel, ...
Frontiers in neuroscience 9, 163, 2015
922015
Three‐dimensional Fourier encoding of simultaneously excited slices: generalized acquisition and reconstruction framework
B Zahneisen, BA Poser, T Ernst, VA Stenger
Magnetic resonance in medicine 71 (6), 2071-2081, 2014
922014
Impact of acquisition and analysis strategies on cortical depth-dependent fMRI
S Kashyap, D Ivanov, M Havlicek, BA Poser, K Uludağ
Neuroimage 168, 332-344, 2018
852018
Fast spin echo sequences for BOLD functional MRI
BA Poser, DG Norris
Magnetic Resonance Materials in Physics, Biology and Medicine 20, 11-17, 2007
782007
A method for the dynamic correction of B0-related distortions in single-echo EPI at 7 T
B Dymerska, BA Poser, M Barth, S Trattnig, SD Robinson
Neuroimage 168, 321-331, 2018
762018
Das System kann den Vorgang jetzt nicht ausführen. Versuchen Sie es später erneut.
Artikel 1–20