A new polymer gel for magnetic resonance imaging (MRI) radiation dosimetry E Pappas, T Maris, A Angelopoulos, M Paparigopoulou, L Sakelliou, ... Physics in Medicine & Biology 44 (10), 2677, 1999 | 172 | 1999 |
Small SRS photon field profile dosimetry performed using a PinPoint air ion chamber, a diamond detector, a novel silicon‐diode array (DOSI), and polymer gel dosimetry. Analysis … E Pappas, TG Maris, F Zacharopoulou, A Papadakis, S Manolopoulos, ... Medical physics 35 (10), 4640-4648, 2008 | 139 | 2008 |
Experimental determination of the effect of detector size on profile measurements in narrow photon beams E Pappas, TG Maris, A Papadakis, F Zacharopoulou, J Damilakis, ... Medical physics 33 (10), 3700-3710, 2006 | 95 | 2006 |
Narrow stereotactic beam profile measurements using N-vinylpyrrolidone based polymer gels and magnetic resonance imaging E Pappas, I Seimenis, A Angelopoulos, P Georgolopoulou, ... Physics in Medicine & Biology 46 (3), 783, 2001 | 69 | 2001 |
Wide dynamic dose range of VIPAR polymer gel dosimetry P Kipouros, E Pappas, P Baras, D Hatzipanayoti, P Karaiskos, L Sakelliou, ... Physics in Medicine & Biology 46 (8), 2143, 2001 | 61 | 2001 |
Polymer gel dosimetry using a three‐dimensional MRI acquisition technique P Baras, I Seimenis, P Kipouros, P Papagiannis, A Angelopoulos, ... Medical Physics 29 (11), 2506-2516, 2002 | 50 | 2002 |
Relative output factor measurements of a 5 mm diameter radiosurgical photon beam using polymer gel dosimetry E Pappas, L Petrokokkinos, A Angelopoulos, TG Maris, M Kozicki, ... Medical physics 32 (6Part1), 1513-1520, 2005 | 48 | 2005 |
An evaluation of the dosimetric performance characteristics of N-vinylpyrrolidone-based polymer gels AE Papadakis, TG Maris, F Zacharopoulou, E Pappas, G Zacharakis, ... Physics in Medicine & Biology 52 (16), 5069-5083, 2007 | 47 | 2007 |
Dosimetry close to an HDR source using N‐vinylpyrrolidone based polymer gels and magnetic resonance imaging P Papagiannis, E Pappas, P Kipouros, A Angelopoulos, L Sakelliou, ... Medical physics 28 (7), 1416-1426, 2001 | 44 | 2001 |
Dosimetric performance of the Elekta Unity MR-linac system: 2D and 3D dosimetry in anthropomorphic inhomogeneous geometry E Pappas, G Kalaitzakis, T Boursianis, E Zoros, K Zourari, EP Pappas, ... Physics in Medicine & Biology 64 (22), 225009, 2019 | 39 | 2019 |
Dosimetric characteristics of a new polymer gel and their dependence on post-preparation and post-irradiation time: effect on X-ray beam profile measurements MV Papoutsaki, TG Maris, E Pappas, AE Papadakis, J Damilakis Physica Medica 29 (5), 453-460, 2013 | 39 | 2013 |
Characterization of a novel 3D printed patient specific phantom for quality assurance in cranial stereotactic radiosurgery applications DN Makris, EP Pappas, E Zoros, N Papanikolaou, DL Saenz, ... Physics in Medicine & Biology 64 (10), 105009, 2019 | 28 | 2019 |
A systematic analysis of 2 monoisocentric techniques for the treatment of multiple brain metastases G Narayanasamy, S Stathakis, AN Gutierrez, E Pappas, R Crownover, ... Technology in Cancer Research & Treatment 16 (5), 639-644, 2017 | 27 | 2017 |
Gel dosimetry for three dimensional proton range measurements in anthropomorphic geometries M Hillbrand, G Landry, S Ebert, G Dedes, E Pappas, G Kalaitzakis, C Kurz, ... Zeitschrift für Medizinische Physik 29 (2), 162-172, 2019 | 26 | 2019 |
Evaluation of the performance of VIPAR polymer gels using a variety of x-ray and electron beams E Pappas, A Angelopoulos, P Kipouros, L Vlachos, S Xenofos, I Seimenis Physics in Medicine & Biology 48 (5), N65, 2003 | 22 | 2003 |
Animal tissue-based quantitative comparison of dual-energy CT to SPR conversion methods using high-resolution gel dosimetry KB Niepel, M Stanislawski, M Wuerl, F Doerringer, M Pinto, O Dietrich, ... Physics in Medicine & Biology 66 (7), 075009, 2021 | 17 | 2021 |
Dosimetric validation for an automatic brain metastases planning software using single‐isocenter dynamic conformal arcs H Liu, J Li, E Pappas, D Andrews, J Evans, M Werner‐Wasik, Y Yu, ... Journal of Applied Clinical Medical Physics 17 (5), 142-156, 2016 | 16 | 2016 |
Dosimetric and localization accuracy of Elekta high definition dynamic radiosurgery DL Saenz, Y Li, K Rasmussen, S Stathakis, E Pappas, N Papanikolaou Physica Medica 54, 146-151, 2018 | 13 | 2018 |
End to end comparison of surface‐guided imaging versus stereoscopic X‐rays for the SRS treatment of multiple metastases with a single isocenter using 3D anthropomorphic gel … V Bry, D Saenz, E Pappas, G Kalaitzakis, N Papanikolaou, K Rasmussen Journal of Applied Clinical Medical Physics 23 (5), e13576, 2022 | 11 | 2022 |
Study of VIPAR gel dosimeter dose range improvement M Kozicki, L Petrokokkinos, P Papagiannis, L Sakelliou, A Angelopoulos, ... Medical Physics Proceedings of the jointly held Congresses ICMP, 14-17, 2005 | 11 | 2005 |