Follow
Antonio Completo
Antonio Completo
Verified email at ua.pt
Title
Cited by
Cited by
Year
Development of a planar multibody model of the human knee joint
M Machado, P Flores, JCP Claro, J Ambrósio, M Silva, A Completo, ...
Nonlinear Dynamics 60, 459-478, 2010
1212010
Strain shielding in proximal tibia of stemmed knee prosthesis: experimental study
A Completo, F Fonseca, JA Simoes
Journal of biomechanics 41 (3), 560-566, 2008
1202008
Fundamentos de biomecânica músculo-esquelética e ortopédica
A Completo, F Fonseca
Porto: publindústria, 2011
922011
The influence of different tibial stem designs in load sharing and stability at the cement–bone interface in revision TKA
A Completo, JA Simões, F Fonseca, M Oliveira
The Knee 15 (3), 227-232, 2008
922008
Straight, semi-anatomic and anatomic TMJ implants: the influence of condylar geometry and bone fixation screws
A Ramos, A Completo, C Relvas, M Mesnard, JA Simões
Journal of Cranio-Maxillofacial Surgery 39 (5), 343-350, 2011
842011
Relationship of design features of stemmed tibial knee prosthesis with stress shielding and end-of-stem pain
A Completo, P Talaia, F Fonseca, JA Simões
Materials & Design 30 (4), 1391-1397, 2009
722009
Experimental validation of intact and implanted distal femur finite element models
A Completo, F Fonseca, JA Simoes
Journal of biomechanics 40 (11), 2467-2476, 2007
642007
Mimicking nature: fabrication of 3D anisotropic electrospun polycaprolactone scaffolds for cartilage tissue engineering applications
AF Girao, A Semitela, G Ramalho, A Completo, PAAP Marques
Composites Part B: Engineering 154, 99-107, 2018
622018
Finite element and experimental cortex strains of the intact and implanted tibia
A Completo, F Fonseca, JA Simoes
622007
Revision total knee arthroplasty: the influence of femoral stems in load sharing and stability
A Completo, JA Simoes, F Fonseca
The knee 16 (4), 275-279, 2009
612009
Electrospinning of bioactive polycaprolactone-gelatin nanofibres with increased pore size for cartilage tissue engineering applications
 Semitela, AF Girão, C Fernandes, G Ramalho, I Bdikin, A Completo, ...
Journal of Biomaterials Applications 35 (4-5), 471-484, 2020
582020
Influence of the contact model on the dynamic response of the human knee joint
M Machado, P Flores, J Ambrosio, A Completo
Proceedings of the Institution of Mechanical Engineers, Part K: Journal of …, 2011
542011
3D reduced graphene oxide scaffolds with a combinatorial fibrous-porous architecture for neural tissue engineering
AF Girao, J Sousa, A Dominguez-Bajo, A Gonzalez-Mayorga, I Bdikin, ...
ACS applied materials & interfaces 12 (35), 38962-38975, 2020
532020
Biomechanical evaluation of proximal tibia behaviour with the use of femoral stems in revision TKA: an in vitro and finite element analysis
A Completo, A Rego, F Fonseca, A Ramos, C Relvas, JA Simões
Clinical biomechanics 25 (2), 159-165, 2010
512010
Electrostatic self-assembled graphene oxide-collagen scaffolds towards a three-dimensional microenvironment for biomimetic applications
AF Girão, G Gonçalves, KS Bhangra, JB Phillips, J Knowles, G Irurueta, ...
RSC advances 6 (54), 49039-49051, 2016
442016
Design process of a novel cemented hip femoral stem concept
A Ramos, A Completo, C Relvas, JA Simoes
Materials & Design 33, 313-321, 2012
422012
Biomechanical evaluation of different reconstructive techniques of proximal tibia in revision total knee arthroplasty: An in-vitro and finite element analysis
A Completo, R Duarte, F Fonseca, JA Simões, A Ramos, C Relvas
Clinical Biomechanics 28 (3), 291-298, 2013
342013
Strain shielding in distal femur after patellofemoral arthroplasty under different activity conditions
S Meireles, A Completo, JA Simões, P Flores
Journal of biomechanics 43 (3), 477-484, 2010
332010
Biomechanical analysis of total elbow replacement with unlinked iBP prosthesis: an in vitro and finite element analysis
A Completo, J Pereira, F Fonseca, A Ramos, C Relvas, J Simões
Clinical Biomechanics 26 (10), 990-997, 2011
312011
A new press-fit stem concept to reduce the risk of end-of-stem pain at revision TKA: a pre-clinical study
A Completo, F Fonseca, JA Simões, A Ramos, C Relvas
The Knee 19 (5), 537-542, 2012
292012
The system can't perform the operation now. Try again later.
Articles 1–20