Florian Meier
Florian Meier
Jena University Hospital and Max Planck Institute of Biochemistry
Verified email at biochem.mpg.de
Title
Cited by
Cited by
Year
BoxCar acquisition method enables single-shot proteomics at a depth of 10,000 proteins in 100 minutes
F Meier, PE Geyer, SV Winter, J Cox, M Mann
Nature Methods 15 (6), 440-448, 2018
1612018
Online parallel accumulation–serial fragmentation (PASEF) with a novel trapped ion mobility mass spectrometer
F Meier, AD Brunner, S Koch, H Koch, M Lubeck, M Krause, N Goedecke, ...
Molecular & Cellular Proteomics 17 (12), i-2545, 2018
1492018
The Impact II, a very high-resolution quadrupole time-of-flight instrument (QTOF) for deep shotgun proteomics
S Beck, A Michalski, O Raether, M Lubeck, S Kaspar, N Goedecke, ...
Molecular & Cellular Proteomics 14 (7), 2014-2029, 2015
1322015
Parallel accumulation–serial fragmentation (PASEF): Multiplying sequencing speed and sensitivity by synchronized scans in a trapped ion mobility device
F Meier, S Beck, N Grassl, M Lubeck, MA Park, O Raether, M Mann
Journal of proteome research 14 (12), 5378-5387, 2015
1252015
Region and cell-type resolved quantitative proteomic map of the human heart
S Doll, M Dressen, PE Geyer, DN Itzhak, C Braun, SA Doppler, F Meier, ...
Nature communications 8 (1), 1-13, 2017
1172017
A novel LC system embeds analytes in pre-formed gradients for rapid, ultra-robust proteomics
N Bache, PE Geyer, DB Bekker-Jensen, O Hoerning, L Falkenby, PV Treit, ...
Molecular & Cellular Proteomics 17 (11), 2284-2296, 2018
852018
EASI-tag enables accurate multiplexed and interference-free MS2-based proteome quantification
SV Winter, F Meier, C Wichmann, J Cox, M Mann, F Meissner
Nature Methods 15 (7), 527-530, 2018
502018
Plasma proteome profiling reveals dynamics of inflammatory and lipid homeostasis markers after Roux-en-Y gastric bypass surgery
NJW Albrechtsen, PE Geyer, S Doll, PV Treit, KN Bojsen-M°ller, ...
Cell systems 7 (6), 601-612. e3, 2018
452018
Trapped ion mobility spectrometry and PASEF enable in-depth lipidomics from minimal sample amounts
CG Vasilopoulou, K Sulek, AD Brunner, NS Meitei, U Schweiger-Hufnagel, ...
Nature Communications 11 (1), 1-11, 2020
372020
MaxQuant. Live enables global targeting of more than 25,000 peptides
C Wichmann, F Meier, SV Winter, AD Brunner, J Cox, M Mann
Molecular & Cellular Proteomics 18 (5), 982-994, 2019
322019
On the isobaric space of 25‐hydroxyvitamin D in human serum: potential for interferences in liquid chromatography/tandem mass spectrometry, systematic errors and accuracy issues
Y Qi, T Geib, P Schorr, F Meier, DA Volmer
Rapid Communications in Mass Spectrometry 29 (1), 1-9, 2015
322015
Novel Galvanic Nanostructures of Ag and Pd for Efficient Laser Desorption/Ionization of Low Molecular Weight Compounds
YE Silina, F Meier, VA Nebolsin, M Koch, DA Volmer
Journal of the American Society for Mass Spectrometry 25 (5), 841-851, 2014
322014
diaPASEF: parallel accumulation–serial fragmentation combined with data-independent acquisition
F Meier, AD Brunner, M Frank, A Ha, I Bludau, E Voytik, ...
Nature Methods 17 (12), 1229-1236, 2020
27*2020
International ring trial of a high resolution targeted metabolomics and lipidomics platform for serum and plasma analysis
JW Thompson, KJ Adams, J Adamski, Y Asad, D Borts, JA Bowden, ...
Analytical chemistry 91 (22), 14407-14416, 2019
212019
A simple micro‐extraction plate assay for automated LC‐MS/MS analysis of human serum 25‐hydroxyvitamin D levels
T Geib, F Meier, P Schorr, F Lammert, CS Stokes, DA Volmer
Journal of Mass Spectrometry 50 (1), 275-279, 2015
202015
Silver dopants for targeted and untargeted direct analysis of unsaturated lipids via infrared matrix‐assisted laser desorption electrospray ionization (IR‐MALDESI)
F Meier, KP Garrard, DC Muddiman
Rapid Communications in Mass Spectrometry 28 (22), 2461-2470, 2014
182014
TransOmic analysis of forebrain sections in Sp2 conditional knockout embryonic mice using IR-MALDESI imaging of lipids and LC-MS/MS label-free proteomics
P Loziuk, F Meier, C Johnson, HT Ghashghaei, DC Muddiman
Analytical and bioanalytical chemistry 408 (13), 3453-3474, 2016
112016
Ultra-high sensitivity mass spectrometry quantifies single-cell proteome changes upon perturbation
AD Brunner, M Thielert, C Vasilopoulou, C Ammar, F Coscia, A Mund, ...
bioRxiv, 2020
32020
Deep learning the collisional cross sections of the peptide universe from a million experimental values
F Meier, ND K÷hler, AD Brunner, JMH Wanka, E Voytik, MT Strauss, ...
Nature Communications 12 (1), 1-12, 2021
2*2021
A paired liver biopsy and plasma proteomics study reveals circulating biomarkers for alcohol-related liver disease
L Niu, M Thiele, PE Geyer, DN Rasmussen, HE Webel, A Santos, R Gupta, ...
bioRxiv, 2020
12020
The system can't perform the operation now. Try again later.
Articles 1–20