Follow
Miklós Kassai
Miklós Kassai
Associate Professor
Verified email at epget.bme.hu - Homepage
Title
Cited by
Cited by
Year
Evaluation of defrosting methods for air-to-air heat/energy exchangers on energy consumption of ventilation
MR Nasr, M Kassai, G Ge, CJ Simonson
Applied Energy 151, 32-40, 2015
792015
Performance investigation of liquid-to-air membrane energy exchanger under low solution/air heat capacity rates ratio conditions
M Kassai, CJ Simonson
Building services engineering research and technology 36 (5), 535-545, 2015
302015
Investigation of the energy recovery potentials in ventilation systems in different climates
M Kassai, L Poleczky, L Al-Hyari, L Kajtar, J Nyers
Facta Universitatis, Series: Mechanical Engineering 16 (2), 203-217, 2018
252018
Experimental investigation on the effectiveness of sorption energy recovery wheel in ventilation system
M Kassai
Experimental Heat Transfer 31 (2), 106-120, 2018
252018
Experimental investigation of carbon dioxide cross-contamination in sorption energy recovery wheel in ventilation system
M Kassai
Building Services Engineering Research and Technology 39 (4), 463-474, 2018
232018
Computerised simulation of the energy consumption of air handling units
L Kajtar, M Kassai, L Banhidi
Energy and Buildings 45, 54-59, 2012
212012
Diffusion-magnetic resonance imaging predicts decline of kidney function in chronic kidney disease and in patients with a kidney allograft
L Berchtold, LA Crowe, C Combescure, M Kassaï, I Aslam, D Legouis, ...
Kidney international 101 (4), 804-813, 2022
202022
Experimental effectiveness investigation of liquid-to-air membrane energy exchangers under low heat capacity rates conditions
M Kassai, CJ Simonson
Experimental Heat Transfer 29 (4), 445-455, 2016
162016
Experimental optimization of energy consumption for direct current refrigerator by PID controller tuning and comparison with ON/OFF refrigerator
M Kassai, L Kajtar, J Nyers
Thermal Science 23 (2 Part B), 941-952, 2019
152019
Prediction of the HVAC energy demand and consumption of a single family house with different calculation methods
M Kassai
Energy Procedia 112, 585-594, 2017
152017
Dehumidification performance investigation of run-around membrane energy exchanger system
M Kassai, G Ge, CJ Simonson
Thermal Science 20 (6), 1927-1938, 2016
152016
Effectiveness and humidification capacity investigation of liquid-to-air membrane energy exchanger under low heat capacity ratios at winter air conditions
M Kassai
Journal of Thermal Science 24, 391-397, 2015
142015
Investigation of ventilation energy recovery with polymer membrane material-based counter-flow energy exchanger for nearly zero-energy buildings
M Kassai, L Al-Hyari
Energies 12 (9), 1727, 2019
132019
Development of TRNSYS model for energy performance simulation of variable refrigerant flow air-conditioning system combined with energy recovery ventilation
L Al-Hyari, M Kassai
International Journal of Green Energy 18 (4), 390-401, 2021
122021
A developed method for energy saving prediction of heat-and energy recovery units
M Kassai
Energy Procedia 85, 311-319, 2016
102016
Energy performance investigation of a direct expansion ventilation cooling system with a heat wheel
M Kassai
Energies 12 (22), 4267, 2019
92019
Cooling energy saved investigation of air-to-air heat-and energy exchangers
M Kassai, L Kajtar
Proceedings Express, 6-10, 2016
92016
A developed procedure to predict annual heating energy by heat-and energy-recovery technologies in different climate European countries
M Kassai, MR Nasr, CJ Simonson
Energy and Buildings 109, 267-273, 2015
92015
A new calculation procedure to analyse the energy consumption of air handling units
L Kajtár, M Kassai
Periodica Polytechnica Mechanical Engineering 54 (1), 21-26, 2010
92010
Physiologically variable ventilation reduces regional lung inflammation in a pediatric model of acute respiratory distress syndrome
A Dos Santos Rocha, GH Fodor, M Kassai, L Degrugilliers, S Bayat, ...
Respiratory research 21, 1-11, 2020
82020
The system can't perform the operation now. Try again later.