Folgen
Liliana Stolarczyk
Liliana Stolarczyk
Dansk Center for Partikelterapi
Bestätigte E-Mail-Adresse bei rm.dk
Titel
Zitiert von
Zitiert von
Jahr
Photon dosimetry methods outside the target volume in radiation therapy: Optically stimulated luminescence (OSL), thermoluminescence (TL) and radiophotoluminescence (RPL) dosimetry
Ž Knežević, L Stolarczyk, I Bessieres, JM Bordy, S Miljanić, P Olko
Radiation measurements 57, 9-18, 2013
952013
Measurement of stray radiation within a scanning proton therapy facility: EURADOS WG9 intercomparison exercise of active dosimetry systems
J Farah, V Mares, M Romero‐Expósito, S Trinkl, C Domingo, V Dufek, ...
Medical physics 42 (5), 2572-2584, 2015
692015
Facility for proton radiotherapy of eye cancer at IFJ PAN in Krakow
J Swakon, P Olko, D Adamczyk, T Cywicka-Jakiel, J Dabrowska, B Dulny, ...
Radiation Measurements 45 (10), 1469-1471, 2010
542010
Dose distribution of secondary radiation in a water phantom for a proton pencil beam—EURADOS WG9 intercomparison exercise
L Stolarczyk, S Trinkl, M Romero-Expósito, N Mojżeszek, I Ambrozova, ...
Physics in Medicine & Biology 63 (8), 085017, 2018
422018
Out-of-field dose measurements for 3D conformal and intensity modulated radiotherapy of a paediatric brain tumour
M Majer, L Stolarczyk, M De Saint-Hubert, D Kabat, Ž Knežević, S Miljanić, ...
Radiation protection dosimetry 176 (3), 331-340, 2017
412017
A comprehensive spectrometry study of a stray neutron radiation field in scanning proton therapy
V Mares, M Romero-Expósito, J Farah, S Trinkl, C Domingo, M Dommert, ...
Physics in Medicine & Biology 61 (11), 4127, 2016
412016
Radiotherapy out-of-field dosimetry: Experimental and computational results for photons in a water tank
JM Bordy, I Bessieres, E d'Agostino, C Domingo, F d'Errico, A di Fulvio, ...
Radiation measurements 57, 29-34, 2013
372013
Ion recombination and polarity correction factors for a plane–parallel ionization chamber in a proton scanning beam
M Liszka, L Stolarczyk, M Kłodowska, A Kozera, D Krzempek, ...
Medical physics 45 (1), 391-401, 2018
272018
Measurement of stray neutron doses inside the treatment room from a proton pencil beam scanning system
N Mojżeszek, J Farah, M Kłodowska, O Ploc, L Stolarczyk, ...
Physica Medica 34, 80-84, 2017
262017
Out-of-field doses for scanning proton radiotherapy of shallowly located paediatric tumours—a comparison of range shifter and 3D printed compensator
A Wochnik, L Stolarczyk, I Ambrožová, M Davidkova, M De Saint-Hubert, ...
Physics in Medicine & Biology 66 (3), 035012, 2021
232021
Comparison of response of passive dosimetry systems in scanning proton radiotherapy—a study using paediatric anthropomorphic phantoms
Ž Knežević, I Ambrozova, C Domingo, M De Saint-Hubert, M Majer, ...
Radiation protection dosimetry 180 (1-4), 256-260, 2018
222018
Out-of-field doses in children treated for large arteriovenous malformations using hypofractionated gamma knife radiosurgery and intensity-modulated radiation therapy
M De Saint-Hubert, M Majer, H Hršak, Z Heinrich, Ž Knežević, S Miljanić, ...
Radiation protection dosimetry 181 (2), 100-110, 2018
192018
EURADOS strategic research agenda 2020: vision for the dosimetry of ionising radiation
RM Harrison, E Ainsbury, J Alves, JF Bottollier-Depois, B Breustedt, ...
Radiation protection dosimetry 194 (1), 42-56, 2021
182021
The European radiation dosimetry group–Review of recent scientific achievements
W Rühm, E Ainsbury, B Breustedt, M Caresana, P Gilvin, Ž Knežević, ...
Radiation Physics and Chemistry 168, 108514, 2020
172020
Clinical simulations of prostate radiotherapy using BOMAB-like phantoms: results for photons
S Miljanić, I Bessieres, JM Bordy, F d'Errico, A Di Fulvio, D Kabat, ...
Radiation measurements 57, 35-47, 2013
172013
Out‐of‐field doses in pediatric craniospinal irradiations with 3D‐CRT, VMAT, and scanning proton radiotherapy: a phantom study
M Majer, I Ambrožová, M Davídková, M De Saint‐Hubert, M Kasabašić, ...
Medical physics 49 (4), 2672-2683, 2022
162022
The influence of nuclear models and Monte Carlo radiation transport codes on stray neutron dose estimations in proton therapy
M De Saint-Hubert, J Farah, M Klodowska, MT Romero-Expósito, ...
Radiation Measurements 150, 106693, 2022
162022
Calibration of Gafchromic EBT3 film for dosimetry of scanning proton pencil beam (PBS)
D Krzempek, G Mianowska, N Bassler, L Stolarczyk, R Kopeć, ...
Radiation protection dosimetry 180 (1-4), 324-328, 2018
162018
Evaluation of risk of secondary cancer occurrence after proton radiotherapy of ocular tumours
L Stolarczyk, T Cywicka-Jakiel, T Horwacik, P Olko, J Swakon, ...
Radiation measurements 46 (12), 1944-1947, 2011
162011
High-dose high-temperature emission of LiF: Mg, Cu, P: Thermally and radiation induced loss & recovery of its sensitivity
B Obryk, K Skowrońska, A Sas-Bieniarz, L Stolarczyk, P Bilski
Radiation measurements 56, 171-178, 2013
142013
Das System kann den Vorgang jetzt nicht ausführen. Versuchen Sie es später erneut.
Artikel 1–20