Needle–tissue interaction forces–A survey of experimental data DJ van Gerwen, J Dankelman, JJ van den Dobbelsteen Medical engineering & physics 34 (6), 665-680, 2012 | 293 | 2012 |
Three-dimensional needle shape reconstruction using an array of fiber bragg grating sensors RJ Roesthuis, M Kemp, JJ van den Dobbelsteen, S Misra IEEE/ASME transactions on mechatronics 19 (4), 1115-1126, 2013 | 291 | 2013 |
Sensory integration does not lead to sensory calibration JBJ Smeets, JJ van den Dobbelsteen, DDJ de Grave, RJ van Beers, ... Proceedings of the National Academy of Sciences 103 (49), 18781-18786, 2006 | 239 | 2006 |
Design choices in needle steering—A review NJ Van De Berg, DJ Van Gerwen, J Dankelman, JJ Van Den Dobbelsteen IEEE/ASME Transactions on Mechatronics 20 (5), 2172-2183, 2014 | 156 | 2014 |
Force feedback and basic laparoscopic skills MK Chmarra, J Dankelman, JJ van den Dobbelsteen, FW Jansen Surgical endoscopy 22, 2140-2148, 2008 | 119 | 2008 |
Forces applied to the maxillary incisors during video-assisted intubation RA Lee, AAJ van Zundert, RLJG Maassen, RJ Willems, LP Beeke, ... Anesthesia & Analgesia 108 (1), 187-191, 2009 | 109 | 2009 |
Force measurement platform for training and assessment of laparoscopic skills T Horeman, SP Rodrigues, FW Jansen, J Dankelman, ... Surgical endoscopy 24, 3102-3108, 2010 | 105 | 2010 |
Sterilization of disposable face masks by means of standardized dry and steam sterilization processes; an alternative in the fight against mask shortages due to COVID-19 P De Man, B van Straten, J van den Dobbelsteen, A Van Der Eijk, ... Journal of Hospital Infection 105 (2), 356-357, 2020 | 101 | 2020 |
Design of an actively controlled steerable needle with tendon actuation and FBG-based shape sensing NJ van de Berg, J Dankelman, JJ van den Dobbelsteen Medical engineering & physics 37 (6), 617-622, 2015 | 97 | 2015 |
Assessment of laparoscopic skills based on force and motion parameters T Horeman, J Dankelman, FW Jansen, JJ van den Dobbelsteen IEEE Transactions on Biomedical Engineering 61 (3), 805-813, 2013 | 97 | 2013 |
Accuracy of needle position measurements using fiber Bragg gratings K Henken, D Van Gerwen, J Dankelman, J Van Den Dobbelsteen Minimally Invasive Therapy & Allied Technologies 21 (6), 408-414, 2012 | 92 | 2012 |
Error Analysis of FBG-Based Shape Sensors for Medical Needle Tracking KR Henken, J Dankelman, JJ van den Dobbelsteen, LK Cheng, ... Transactions on Mechatronics, 1-9, 2013 | 90 | 2013 |
Force parameters for skills assessment in laparoscopy T Horeman, SP Rodrigues, FW Jansen, J Dankelman, ... IEEE Transactions on Haptics 5 (4), 312-322, 2011 | 74 | 2011 |
Visual force feedback improves knot-tying security T Horeman, MD Blikkendaal, D Feng, A van Dijke, FW Jansen, ... Journal of surgical education 71 (1), 133-141, 2014 | 72 | 2014 |
Endpoints of arm movements to visual targets JJ van den Dobbelsteen, E Brenner, JB Smeets Experimental Brain Research 138, 279-287, 2001 | 72 | 2001 |
Visual force feedback in laparoscopic training T Horeman, SP Rodrigues, JJ van den Dobbelsteen, FW Jansen, ... Surgical endoscopy 26, 242-248, 2012 | 67 | 2012 |
Friction dynamics of trocars JJ Van den Dobbelsteen, A Schooleman, J Dankelman Surgical endoscopy 21, 1338-1343, 2007 | 58 | 2007 |
Needle placement errors: do we need steerable needles in interventional radiology? TL De Jong, NJ Van De Berg, L Tas, A Moelker, J Dankelman, ... Medical Devices: Evidence and Research, 259-265, 2018 | 57 | 2018 |
The art of electrosurgery: trainees and experts FC Meeuwsen, ACP Guédon, EA Arkenbout, M van der Elst, J Dankelman, ... Surgical innovation 24 (4), 373-378, 2017 | 53 | 2017 |
Suturing intraabdominal organs: when do we cause tissue damage? SP Rodrigues, T Horeman, J Dankelman, JJ van den Dobbelsteen, ... Surgical endoscopy 26, 1005-1009, 2012 | 52 | 2012 |