Influence of material coupling and assembly condition on the magnitude of micromotion at the stem–neck interface of a modular hip endoprosthesis SY Jauch, G Huber, E Hoenig, M Baxmann, TM Grupp, MM Morlock Journal of biomechanics 44 (9), 1747-1751, 2011 | 112 | 2011 |
Influence of the screw augmentation technique and a diameter increase on pedicle screw fixation in the osteoporotic spine: pullout versus fatigue testing RA Kueny, JP Kolb, W Lehmann, K Püschel, MM Morlock, G Huber European Spine Journal 23 (10), 2196-2202, 2014 | 74 | 2014 |
The influence of component design, bearing clearance and axial load on the squeaking characteristics of ceramic hip articulations A Hothan, G Huber, C Weiss, N Hoffmann, M Morlock Journal of biomechanics 44 (5), 837-841, 2011 | 71 | 2011 |
Squeak in hip endoprosthesis systems: an experimental study and a numerical technique to analyze design variants C Weiss, P Gdaniec, NP Hoffmann, A Hothan, G Huber, MM Morlock Medical engineering & physics 32 (6), 604-609, 2010 | 63 | 2010 |
Effects of parathyroid hormone on bone mass, bone strength, and bone regeneration in male rats with type 2 diabetes mellitus C Hamann, AK Picke, GM Campbell, M Balyura, M Rauner, R Bernhardt, ... Endocrinology 155 (4), 1197-1206, 2014 | 54 | 2014 |
Insufficient stability of pedicle screws in osteoporotic vertebrae: biomechanical correlation of bone mineral density and pedicle screw fixation strength L Weiser, G Huber, K Sellenschloh, L Viezens, K Püschel, MM Morlock, ... European Spine Journal 26 (11), 2891-2897, 2017 | 52 | 2017 |
Does the cement stiffness affect fatigue fracture strength of vertebrae after cement augmentation in osteoporotic patients? JP Kolb, RA Kueny, K Püschel, A Boger, JM Rueger, MM Morlock, ... European Spine Journal 22 (7), 1650-1656, 2013 | 41 | 2013 |
Biomechanical advantage of C1 pedicle screws over C1 lateral mass screws: a cadaveric study F Fensky, RA Kueny, K Sellenschloh, K Püschel, MM Morlock, JM Rueger, ... European Spine Journal 23 (4), 724-731, 2014 | 40 | 2014 |
Micromotions at the taper interface between stem and neck adapter of a bimodular hip prosthesis during activities of daily living SY Jauch, G Huber, K Sellenschloh, H Haschke, M Baxmann, TM Grupp, ... Journal of Orthopaedic Research 31 (8), 1165-1171, 2013 | 39 | 2013 |
Finite element analyses of human vertebral bodies embedded in polymethylmethalcrylate or loaded via the hyperelastic intervertebral disc models provide equivalent predictions … Y Lu, G Maquer, O Museyko, K Püschel, K Engelke, P Zysset, M Morlock, ... Journal of biomechanics 47 (10), 2512-2516, 2014 | 37 | 2014 |
Design parameters and the material coupling are decisive for the micromotion magnitude at the stem–neck interface of bi-modular hip implants SY Jauch, G Huber, H Haschke, K Sellenschloh, MM Morlock Medical engineering & physics 36 (3), 300-307, 2014 | 35 | 2014 |
Shear strength of the human lumbar spine DM Skrzypiec, A Klein, NE Bishop, F Stahmer, K Püschel, H Seidel, ... Clinical Biomechanics 27 (7), 646-651, 2012 | 30 | 2012 |
Deformation characteristics and eigenfrequencies of press-fit acetabular cups A Hothan, G Huber, C Weiss, N Hoffmann, M Morlock Clinical Biomechanics 26 (1), 46-51, 2011 | 29 | 2011 |
Friction-induced whirl vibration: root cause of squeaking in total hip arthroplasty C Weiss, A Hothan, G Huber, MM Morlock, NP Hoffmann Journal of biomechanics 45 (2), 297-303, 2012 | 26 | 2012 |
Assembly force and taper angle difference influence the relative motion at the stem–neck interface of bi-modular hip prostheses H Haschke, SY Jauch-Matt, K Sellenschloh, G Huber, MM Morlock Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2016 | 25 | 2016 |
Estimation of shear load sharing in moderately degenerated human lumbar spine DM Skrzypiec, NE Bishop, A Klein, K Püschel, MM Morlock, G Huber Journal of biomechanics 46 (4), 651-657, 2013 | 25 | 2013 |
Quantification of material loss from the neck piece taper junctions of a bimodular primary hip prosthesis. A retrieval study from 27 failed Rejuvenate bimodular hip arthroplasties D Buente, G Huber, N Bishop, M Morlock The bone & joint journal 97 (10), 1350-1357, 2015 | 24 | 2015 |
Cement augmentation versus extended dorsal instrumentation in the treatment of osteoporotic vertebral fractures: a biomechanical comparison L Weiser, M Dreimann, G Huber, K Sellenschloh, K Püschel, MM Morlock, ... The bone & joint journal 98 (8), 1099-1105, 2016 | 22 | 2016 |
CAD–CAM plates versus conventional fixation plates for primary mandibular reconstruction: A biomechanical in vitro analysis C Rendenbach, K Sellenschloh, L Gerbig, MM Morlock, ... Journal of Cranio-Maxillofacial Surgery 45 (11), 1878-1883, 2017 | 21 | 2017 |
Compressive strength of elderly vertebrae is reduced by disc degeneration and additional flexion G Maquer, J Schwiedrzik, G Huber, MM Morlock, PK Zysset Journal of the mechanical behavior of biomedical materials 42, 54-66, 2015 | 21 | 2015 |