Follow
Karl Landheer
Title
Cited by
Cited by
Year
Advanced single voxel 1H magnetic resonance spectroscopy techniques in humans: Experts' consensus recommendations
G Öz, DK Deelchand, JP Wijnen, V Mlynárik, L Xin, R Mekle, R Noeske, ...
NMR in Biomedicine 34 (5), e4236, 2021
1152021
Across‐vendor standardization of semi‐LASER for single‐voxel MRS at 3T
DK Deelchand, A Berrington, R Noeske, JM Joers, A Arani, J Gillen, ...
NMR in Biomedicine 34 (5), e4218, 2021
662021
Quantifying the metabolic signature of multiple sclerosis by in vivo proton magnetic resonance spectroscopy: current challenges and future outlook in the translation from …
KM Swanberg, K Landheer, D Pitt, C Juchem
Frontiers in Neurology 10, 489792, 2019
542019
Magnetic resonance Spectrum simulator (MARSS), a novel software package for fast and computationally efficient basis set simulation
K Landheer, KM Swanberg, C Juchem
NMR in Biomedicine 34 (5), e4129, 2021
532021
X-ray coherent scattering form factors of tissues, water and plastics using energy dispersion
BW King, KA Landheer, PC Johns
Physics in Medicine & Biology 56 (14), 4377, 2011
412011
INSPECTOR: free software for magnetic resonance spectroscopy data inspection, processing, simulation and analysis
M Gajdošík, K Landheer, KM Swanberg, C Juchem
Scientific reports 11 (1), 2094, 2021
362021
Dephasing optimization through coherence order pathway selection (DOTCOPS) for improved crusher schemes in MR spectroscopy
K Landheer, C Juchem
Magnetic resonance in medicine 81 (4), 2209-2222, 2019
342019
Concentration and effective T2 relaxation times of macromolecules at 3T
K Landheer, M Gajdošík, M Treacy, C Juchem
Magnetic Resonance in Medicine 84 (5), 2327-2337, 2020
302020
Frequency drift in MR spectroscopy at 3T
SCN Hui, M Mikkelsen, HJ Zöllner, V Ahluwalia, S Alcauter, L Baltusis, ...
NeuroImage 241, 118430, 2021
282021
Theoretical description of modern 1H in Vivo magnetic resonance spectroscopic pulse sequences
K Landheer, RF Schulte, MS Treacy, KM Swanberg, C Juchem
Journal of Magnetic Resonance Imaging 51 (4), 1008-1029, 2020
242020
A semi‐LASER, single‐voxel spectroscopic sequence with a minimal echo time of 20.1 ms in the human brain at 3 T
K Landheer, M Gajdošík, C Juchem
NMR in Biomedicine 33 (9), e4324, 2020
232020
Multiancestry exome sequencing reveals INHBE mutations associated with favorable fat distribution and protection from diabetes
P Akbari, OA Sosina, J Bovijn, K Landheer, JB Nielsen, M Kim, S Aykul, ...
Nature communications 13 (1), 4844, 2022
202022
Are Cramér‐Rao lower bounds an accurate estimate for standard deviations in in vivo magnetic resonance spectroscopy?
K Landheer, C Juchem
NMR in Biomedicine 34 (7), e4521, 2021
202021
Simultaneous optimization of crusher and phase cycling schemes for magnetic resonance spectroscopy: an extension of dephasing optimization through coherence order pathway selection
K Landheer, C Juchem
Magnetic Resonance in Medicine 83 (2), 391-402, 2020
192020
A rapid inversion technique for the measurement of longitudinal relaxation times of brain metabolites: application to lactate in high‐grade gliomas at 3 T
K Landheer, A Sahgal, S Myrehaug, AP Chen, CH Cunningham, ...
NMR in Biomedicine 29 (10), 1381-1390, 2016
162016
Synchrotron-based coherent scatter x-ray projection imaging using an array of monoenergetic pencil beams
K Landheer, PC Johns
Review of Scientific Instruments 83 (9), 2012
162012
Diffusion‐weighted J‐resolved spectroscopy
K Landheer, R Schulte, B Geraghty, C Hanstock, AP Chen, ...
Magnetic Resonance in Medicine 78 (4), 1235-1245, 2017
132017
Constrained source space MR spectroscopy: multiple voxels, no gradient readout
K Landheer, A Sahgal, S Das, SJ Graham
American Journal of Neuroradiology 36 (8), 1436-1443, 2015
92015
Elevated homocarnosine and GABA in subject on isoniazid as assessed through 1H MRS at 7T
K Landheer, H Prinsen, OA Petroff, DL Rothman, C Juchem
Analytical biochemistry 599, 113738, 2020
72020
Coherent x-ray scatter projection imaging using an array of monoenergetic pencil beams
K Landheer, PC Johns
Chemical, Biological, Radiological, Nuclear, and Explosives (CBRNE) Sensing …, 2012
72012
The system can't perform the operation now. Try again later.
Articles 1–20