Peter Woias
Titel
Zitiert von
Zitiert von
Jahr
Micropumps—past, progress and future prospects
P Woias
Sensors and Actuators B: Chemical 105 (1), 28-38, 2005
6542005
Numerical and experimental investigations on liquid mixing in static micromixers
M Engler, N Kockmann, T Kiefer, P Woias
Chemical Engineering Journal 101 (1-3), 315-322, 2004
3282004
Characterization of different beam shapes for piezoelectric energy harvesting
F Goldschmidtboeing, P Woias
Journal of micromechanics and microengineering 18 (10), 104013, 2008
3072008
Design and fabrication of MEMS thermoelectric generators with high temperature efficiency
T Huesgen, P Woias, N Kockmann
Sensors and Actuators A: Physical 145, 423-429, 2008
2112008
Convective mixing and chemical reactions in microchannels with high flow rates
N Kockmann, T Kiefer, M Engler, P Woias
Sensors and Actuators B: Chemical 117 (2), 495-508, 2006
2062006
Robust design of gas and liquid micropumps
M Richter, R Linnemann, P Woias
Sensors and Actuators A: Physical 68 (1-3), 480-486, 1998
1981998
A self-priming and bubble-tolerant piezoelectric silicon micropump for liquids and gases
R Linnemann, P Woias, CD Senfft, JA Ditterich
Proceedings MEMS 98. IEEE. Eleventh Annual International Workshop on Micro …, 1998
1871998
Protein detection with a novel ISFET-based zeta potential analyzer
S Koch, P Woias, LK Meixner, S Drost, H Wolf
Biosensors and Bioelectronics 14 (4), 413-421, 1999
1781999
Slow pH response effects of silicon nitride ISFET sensors
P Woias, L Meixner, P Fröstl
Sensors and Actuators B: Chemical 48 (1-3), 501-504, 1998
1571998
Micropumps: summarizing the first two decades
P Woias
Microfluidics and BioMEMS 4560, 39-52, 2001
1472001
Characterization of laminar transient flow regimes and mixing in T-shaped micromixers
S Dreher, N Kockmann, P Woias
heat transfer engineering 30 (1-2), 91-100, 2009
1412009
Microchannels for applications in liquid dosing and flow-rate measurement
M Richter, P Woias, D Weiβ
Sensors and Actuators A: Physical 62 (1-3), 480-483, 1997
1371997
A quartz crystal biosensor for measurement in liquids
C Kößlinger, S Drost, F Aberl, H Wolf, S Koch, P Woias
Biosensors and Bioelectronics 7 (6), 397-404, 1992
1351992
Bidirectional frequency tuning of a piezoelectric energy converter based on a cantilever beam
C Eichhorn, F Goldschmidtboeing, P Woias
Journal of Micromechanics and Microengineering 19 (9), 094006, 2009
1302009
Modelling the short-time response of ISFET sensors
P Woias, L Meixner, D Amandi, M Schönberger
Sensors and Actuators B: Chemical 24 (1-3), 211-217, 1995
1291995
A smart and self-sufficient frequency tunable vibration energy harvester
C Eichhorn, R Tchagsim, N Wilhelm, P Woias
Journal of Micromechanics and Microengineering 21 (10), 104003, 2011
982011
Vibration harvesting in traffic tunnels to power wireless sensor nodes
M Wischke, M Masur, M Kröner, P Woias
Smart Materials and Structures 20 (8), 085014, 2011
912011
Simulation and experimental investigation of pressure loss and heat transfer in microchannel networks containing bends and T-junctions
D Haller, P Woias, N Kockmann
International Journal of Heat and Mass Transfer 52 (11-12), 2678-2689, 2009
842009
A high performance bidirectional micropump for a novel artificial sphincter system
A Doll, M Heinrichs, F Goldschmidtboeing, HJ Schrag, UT Hopt, P Woias
Sensors and Actuators A: Physical 130, 445-453, 2006
832006
HIV serology using piezoelectric immunosensors
F Aberl, H Wolf, C Kößlinger, S Drost, P Woias, S Koch
Sensors and Actuators B: Chemical 18 (1-3), 271-275, 1994
831994
Das System kann den Vorgang jetzt nicht ausführen. Versuchen Sie es später erneut.
Artikel 1–20