Folgen
Sebastian V. Jansen
Sebastian V. Jansen
Bestätigte E-Mail-Adresse bei ame.rwth-aachen.de - Startseite
Titel
Zitiert von
Zitiert von
Jahr
Flow analysis of ventricular assist device inflow and outflow cannula positioning using a naturally shaped ventricle and aortic branch
M Laumen, T Kaufmann, D Timms, P Schlanstein, S Jansen, S Gregory, ...
Artificial Organs 34 (10), 798-806, 2010
772010
A refractive index-matched facility for fluid–structure interaction studies of pulsatile and oscillating flow in elastic vessels of adjustable compliance
S Burgmann, S Große, W Schröder, J Roggenkamp, S Jansen, F Gräf, ...
Experiments in fluids 47, 865-881, 2009
382009
Structure-dependent gas transfer performance of 3D-membranes for artificial membrane lungs
F Hesselmann, N Scherenberg, P Bongartz, S Djeljadini, M Wessling, ...
Journal of Membrane Science 634, 119371, 2021
202021
Hemodynamics inside the neo‐and native sinus after TAVR: Effects of implant depth and cardiac output on flow field and coronary flow
D Pott, A Sedaghat, C Schmitz, N Werner, T Schmitz‐Rode, U Steinseifer, ...
Artificial organs 45 (1), 68-78, 2021
202021
Particle image velocimetry used to qualitatively validate computational fluid dynamic simulations in an oxygenator: a proof of concept
PC Schlanstein, F Hesselmann, SV Jansen, J Gemsa, TA Kaufmann, ...
Cardiovascular engineering and technology 6, 340-351, 2015
192015
Design modifications and computational fluid dynamic analysis of an outflow cannula for cardiopulmonary bypass
M Neidlin, S Jansen, A Moritz, U Steinseifer, TAS Kaufmann
Annals of biomedical engineering 42, 2048-2057, 2014
192014
Micro-structuring of polycarbonate-urethane surfaces in order to reduce platelet activation and adhesion
J Clauser, K Gester, J Roggenkamp, I Mager, J Maas, SV Jansen, ...
Journal of Biomaterials Science, Polymer Edition 25 (5), 504-518, 2014
142014
Introducing 3D-potting: A novel production process for artificial membrane lungs with superior blood flow design
F Hesselmann, JM Focke, PC Schlanstein, NB Steuer, A Kaesler, ...
Bio-Design and Manufacturing 5 (1), 141-152, 2022
112022
Ghost cell suspensions as blood analogue fluid for macroscopic particle image velocimetry measurements
SV Jansen, I Müller, M Nachtsheim, T Schmitz‐Rode, U Steinseifer
Artificial organs 40 (2), 207-212, 2016
112016
A simple method for the investigation of cell separation effects of blood with physiological hematocrit values
K Gester, SV Jansen, M Stahl, U Steinseifer
Artificial Organs 39 (5), 432-440, 2015
102015
TPMS-based membrane lung with locally-modified permeabilities for optimal flow distribution
F Hesselmann, M Halwes, P Bongartz, M Wessling, C Cornelissen, ...
Scientific reports 12 (1), 7160, 2022
72022
Experimental investigation of right‐left flow balance concepts for a total artificial heart
M Diedrich, S Hildebrand, MK Lommel, T Finocchiaro, E Cuenca, ...
Artificial Organs 45 (4), 364-372, 2021
72021
Three‐dimensional membranes for artificial lungs: Comparison of flow‐induced hemolysis
F Hesselmann, D Arnemann, P Bongartz, M Wessling, C Cornelissen, ...
Artificial organs 46 (3), 412-426, 2022
52022
Controlling the flow balance: In vitro characterization of a pulsatile total artificial heart in preload and afterload sensitivity
S Hildebrand, M Diedrich, M Brockhaus, T Finocchiaro, E Cuenca, ...
Artificial Organs 46 (1), 71-82, 2022
52022
In vitro thrombogenicity testing of pulsatile mechanical circulatory support systems: Design and proof‐of‐concept
MK Brockhaus, MJ Behbahani, F Muris, SV Jansen, T Schmitz‐Rode, ...
Artificial Organs 45 (12), 1513-1521, 2021
52021
Downsizing of a pulsatile total artificial heart—the effect on hemolysis
MK Brockhaus, S Hildebrand, M Diedrich, M Lowes, H De Ben, ...
ASAIO Journal 68 (1), 34-40, 2022
42022
Novel Size-Variable Dedicated Rodent Oxygenator for ECLS Animal Models—Introduction of the “RatOx” Oxygenator and Preliminary In Vitro Results
LJ Strudthoff, J Focke, F Hesselmann, A Kaesler, A Martins Costa, ...
Micromachines 14 (4), 800, 2023
32023
In Vitro and In Vivo Feasibility Study for a Portable VV-ECMO and ECCO2R System
LJ Strudthoff, H Lüken, SV Jansen, J Petran, PC Schlanstein, L Schraven, ...
Membranes 12 (2), 133, 2022
22022
Development of an in-vitro fluorescent haemolysis detection method using ghost cells
SV Jansen
Dissertation, RWTH Aachen University, 2017, 2018
22018
Towards a novel spatially-resolved hemolysis detection method using a fluorescent indicator and loaded ghost cells: Proof-of-principle
SV Jansen, I Müller, N Kiesendahl, T Schmitz-Rode, U Steinseifer
Cardiovascular engineering and technology 6, 376-382, 2015
22015
Das System kann den Vorgang jetzt nicht ausführen. Versuchen Sie es später erneut.
Artikel 1–20