Human-body exergy balance and thermal comfort
M Shukuya, M Saito, K Isawa, T Iwamatsu, H Asada
Report submitted for the final report of the IEA ECBCS Annex 49 (5), 732-743, 2009
362009
Human-body exergy consumption varying with the combination of room air and mean radiant temperatures.
K Isawa, T Komizo, M Shukuya
Journal of Environmental Engineering(Transaction of AIJ), 29-35, 2003
25*2003
Low exergy systems will provide us with the lowest human-body exergy consumption and thermal comfort
K Isawa, T Komizo, M Shukuya
LOWEX NEWS, IEA-ECBCS-Annex 37, 5-6, 2002
202002
Development of simulator for efficient aquaculture of Sillago japonica using reinforcement learning
H Kuroki, H Ikeoka, K Isawa
2020 International Conference on Image Processing and Robotics (ICIP), 1-4, 2020
92020
Human body exergy balance: numerical analysis of an indoor thermal environment of a passive wooden room in summer
K Isawa
Buildings 5 (3), 1055-1069, 2015
62015
Low-Exergy Systems for High Performance Systems and Communities
M Shukuya, M Saito, K Isawa, T Iwamatsu, H Asada
Working Report of IEA ECBS; Annex 49, 2010
62010
Sensitivity Numerical Analysis of Human Body Exergy Balance under an Unsteady-State Thermal Environment—Behavioral Adaptation Induced by Undesirable Cold Storage by Building …
K Isawa, M Shukuya
Health 8 (08), 737, 2016
52016
Working Report of IEA ECBS: human body exergy balance and thermal comfort, International Energy Agency
M Shukuya, M Saito, K Isawa, T Iwamatsu, H Asada
Energy Conservation in Buildings and Community Systems, Annex 49, 0
5
41230 放射冷却パネルによる採冷の研究: その 2. 温冷感・快適感に関する被験者実験 (放射冷房, 環境工学 II)
直井隆行, 森一顕, 伊澤康一, 高橋達, 宿谷昌則
学術講演梗概集. D-2, 環境工学 II, 熱, 湿気, 温熱感, 自然エネルギー, 気流・換 …, 2001
42001
Study on Adapting the Auto Feeding System for Sillago Japonica to Actual Aquaculture Environment
Y Saragai, T Sato, H Kuroki, H Ikeoka, K Isawa
2022 2nd International Conference on Image Processing and Robotics (ICIPRob …, 2022
32022
Research on the sterilization system integrating Vapor Phase Hydrogen Peroxide into the cleanroom air conditioning.
K Isawa, S Tanaka, M Yamaguchi, K Shibuya, T Ono, T Matsuo
Bokin Bobai-Journal of Antibacterial and Antifungal Agents 37 (11), 795-802, 2009
22009
A combined exergy analysis on human-body system and floor heating system
K Isawa, M Shukuya
The 2005 World Sustainable Building Conference Tokyo (SB05 Tokyo), 01-093, 2005
22005
Low exergy systems for high-performance buildings and communities
M Shukuya, M SAITO, K ISAWA
Annex, 0
2
Human body exergy consumption in the thermal environment of shelter gymnasium in winter
K Isawa
International Journal of Exergy 31 (1), 34-48, 2020
12020
Sensitivity Analysis on the Relationship between Building Envelope Material and Human Body Exergy Balance
K Isawa
Energy Procedia 78, 2826-2831, 2015
12015
D-34 塩素系薬剤を用いた微生物対策:(第 10 報) 菌数測定による詳細評価と積算薬剤沈着量の検討
山口一, 伊澤康一, 冨岡一之
空気調和・衛生工学会大会 学術講演論文集 平成 24 年, 1443-1446, 2012
12012
An experimental study on a radiant cooling panel using the evaporation of water
J Hirotani
Proceedings of SB05, September 2005, 2005
12005
Numerical Sensitivity Analysis of Human-body Exergy Balance Under an Unsteady-state Thermal Environment.
K ISAWA
PLEA 2018: Smart and Healthy Within the Two-Degree Limit, 926, 2018
2018
41284 床採温システムのエクセルギー放出・消費特性の試算 (太陽熱床暖房, 環境工学 II)
伊澤康一, 宿谷昌則
学術講演梗概集. D-2, 環境工学 II, 熱, 湿気, 温熱感, 自然エネルギー, 気流・換 …, 2003
2003
A comparison of the human-body exergy balance between low-exergy radiant cooling and conventional convective cooling.
K Isawa, I Takahashi, M Saito, M Shukuya
Journal of Architecture, Planning & Environmental Engineering, 31-38, 2002