Hemolysis at low blood flow rates: in-vitro and in-silico evaluation of a centrifugal blood pump
M Schöps, SH Groß-Hardt, T Schmitz-Rode, U Steinseifer, D Brodie, ...
Journal of translational medicine 19, 1-10, 2021
422021
Evaluation of cover effects on bare stent mechanical response
DJ McGrath, B O’Brien, M Bruzzi, N Kelly, J Clauser, U Steinseifer, ...
Journal of the mechanical behavior of biomedical materials 61, 567-580, 2016
292016
Evaluation of platelet adhesion and activation on polymers: Round-robin study to assess inter-center variability
S Braune, C Sperling, MF Maitz, U Steinseifer, J Clauser, B Hiebl, ...
Colloids and Surfaces B: Biointerfaces 158, 416-422, 2017
262017
A Novel Plasma-Based Fluid for Particle Image Velocimetry (PIV): In-Vitro Feasibility Study of Flow Diverter Effects in Aneurysm Model
J Clauser, MS Knieps, M Büsen, A Ding, T Schmitz-Rode, U Steinseifer, ...
Annals of biomedical engineering 46, 841-848, 2018
192018
PulmoStent: In Vitro to In Vivo Evaluation of a Tissue Engineered Endobronchial Stent
AL Thiebes, N Kelly, CA Sweeney, DJ McGrath, J Clauser, K Kurtenbach, ...
Annals of biomedical engineering 45, 873-883, 2017
182017
Micro-structuring of polycarbonate-urethane surfaces in order to reduce platelet activation and adhesion
J Clauser, K Gester, J Roggenkamp, I Mager, J Maas, SV Jansen, ...
Journal of Biomaterials Science, Polymer Edition 25 (5), 504-518, 2014
142014
Gefitinib/gefitinib microspheres loaded polyurethane constructs as drug-eluting stent coating
W Chen, J Clauser, AL Thiebes, DJ McGrath, N Kelly, ...
European Journal of Pharmaceutical Sciences 103, 94-103, 2017
132017
Selection and fabrication of a non-woven polycarbonate urethane cover for a tissue engineered airway stent
W Chen, J Clauser, AL Thiebes, DJ McGrath, PE McHugh, U Steinseifer, ...
International Journal of Pharmaceutics 514 (1), 255-262, 2016
132016
Miniaturized test loop for the assessment of blood damage by continuous-flow left-ventricular assist devices
E Woelke, M Klein, I Mager, T Schmitz-Rode, U Steinseifer, J Arens, ...
Annals of biomedical engineering 48, 768-779, 2020
112020
Assessing the Thrombogenic Potential of Heart Valve Prostheses: An Approach for a Standardized In-Vitro Method
T Linde, J Clauser, B Meuris, U Steinseifer
Cardiovascular Engineering and Technology 10, 216-224, 2019
102019
Automation of hemocompatibility analysis using image segmentation and supervised classification
JC Clauser, J Maas, J Arens, T Schmitz-Rode, U Steinseifer, B Berkels
Engineering Applications of Artificial Intelligence 97, 104009, 2021
82021
In vitro study on the hemocompatibility of plasma electrolytic oxidation coatings on titanium substrates
M Klein, Y Kuhn, E Woelke, T Linde, C Ptock, A Kopp, T Bletek, ...
Artificial organs 44 (4), 419-427, 2020
82020
Hemocompatibility Evaluation of Biomaterials—The Crucial Impact of Analyzed Area
JC Clauser, J Maas, J Arens, T Schmitz-Rode, U Steinseifer, B Berkels
ACS Biomaterials Science & Engineering 7 (2), 553-561, 2021
72021
Real‐time visualization of platelet interaction with micro structured surfaces
K Gester, S Birtel, J Clauser, U Steinseifer, SJ Sonntag
Artificial Organs 40 (2), 201-207, 2016
72016
In vitro thrombogenicity testing of pulsatile mechanical circulatory support systems: Design and proof‐of‐concept
MK Brockhaus, MJ Behbahani, F Muris, SV Jansen, T Schmitz‐Rode, ...
Artificial Organs 45 (12), 1513-1521, 2021
52021
Validation of a miniaturized test loop for the assessment of human blood damage by continuous-flow left-ventricular assist devices
E Woelke, I Mager, T Schmitz-Rode, U Steinseifer, JC Clauser
Annals of Biomedical Engineering 49 (12), 3165-3175, 2021
42021
Comparison of covered laser-cut and braided respiratory stents: from bench to pre-clinical testing
AL Thiebes, DJ McGrath, N Kelly, CA Sweeney, K Kurtenbach, ...
Annals of Biomedical Engineering 47, 1738-1747, 2019
42019
Regulating blood cell adhesion via surface modification of polyurethanes
J Clauser, K Gester, U Steinseifer, SJ Sonntag
Advances in Polyurethane Biomaterials, 287-318, 2016
42016
Comparison of aspiration catheters with modified standard catheters for treatment of large pulmonary embolism using an in-vitro patho-physiological model
F Schubert, M Tamura, S Bezela, A Weyers, D Kütting, M Menne, ...
Cardiovascular and Interventional Radiology 45, 112-120, 2022
32022
Ghost Cells for Mechanical Circulatory Support In Vitro Testing: A Novel Large Volume Production
M Schöps, JC Clauser, MF Menne, D Faßbänder, T Schmitz‐Rode, ...
Biotechnology journal 15 (4), 1900239, 2020