Follow
Uwe Schichler
Uwe Schichler
Professor of High Voltage Engineering, Graz University of Technology
Verified email at tugraz.at
Title
Cited by
Cited by
Year
Risk assessment on defects in GIS based on PD diagnostics
U Schichler, W Koltunowicz, F Endo, K Feser, A Giboulet, A Girodet, ...
IEEE Transactions on Dielectrics and Electrical Insulation 20 (6), 2165-2172, 2013
782013
Partial discharge measurement at DC voltage—Evaluation and characterization by NoDi∗ pattern
A Pirker, U Schichler
IEEE Transactions on dielectrics and electrical insulation 25 (3), 883-891, 2018
532018
UHF partial discharge detection system for GIS: Application guide for sensitivity verification
U Schichler, W Koltunowicz, D Gautschi, A Girodet, H Hama, K Juhre, ...
VDE High Voltage Technology 2016; ETG-Symposium, 1-9, 2016
462016
Partial discharges at DC voltage-measurement and pattern recognition
A Pirker, U Schichler
2016 International Conference on Condition Monitoring and Diagnosis (CMD …, 2016
382016
UHF PD detection in GIS substations during on-site testing
U Schichler, J Gorablenkow, A Diessner
IET Digital Library, 2000
302000
Very fast transient overvoltage (VFTO) in gas-insulated UHV substations
U Riechert, C Neumann, H Hama, U Schichler, S Okabe, H Ito, E Zaima
CIGRE Advisory Group Report, 56-67, 2010
282010
Application of UHF partial discharge monitoring and expert system diagnosis
J Gorablenkow, T Huecker, U Schichler
Conference Record of the 1998 IEEE International Symposium on Electrical …, 1998
231998
Features and benefits of UHF partial discharge monitoring systems for GIS
N Achatz, J Gorablenkow, U Schichler, B Hampton, J Pearson
Proceedings of 2005 International Symposium on Electrical Insulating …, 2005
222005
Recognition of partial discharges on power units by directional coupling
D Wenzel, U Schichler, H Borsi, E Gockenbach
The 9th ISH. Austria 5626, 1-4, 1995
221995
State of the Art in GIS PD Diagnostics
G Behrmann, W Koltunowicz, U Schichler
2018 Condition Monitoring and Diagnosis (CMD), 1-6, 2018
182018
Experience with UHF PD detection in GIS substations
U Schichler, J Gorablenkow
Proceedings of the 6th International Conference on Properties and …, 2000
182000
A sensitive method for on-site partial discharge detection on XLPE cable joints
U Schichler
Proceedings of 5th International Conference on Properties and Applications …, 1997
181997
On-site application of an advanced PD defect identification system for GIS
A Lapp, HG Kranz, T Hucker, U Schichler
1999 Eleventh International Symposium on High Voltage Engineering 5, 252-255, 1999
171999
Gas insulated systems for HVDC: DC stress at DC and AC systems
F Endo, H Hama, S Okabe, K Juhre, J Kindersberger, S Meijer, ...
HSA, 2012
152012
The impact of insulation monitoring and diagnostics on reliability and exploitation of service life
C Neumann, R Huber, D Meurer, R Plath, U Schichler, S Tenbohlen, ...
GIGRE, C4-201 9, 2006
132006
Dielectric on-site testing of GIL
U Schichler, A Diessner, J Gorablenkow
Proceedings of the 7th International Conference on Properties and …, 2003
132003
Dry air, N2, CO2 and N2/SF6 mixtures for gas-insulated systems
H Hama, S Okabe, R Buhler, D Gautschi, A Girodet, M Hering, ...
Electra 71, 2018
122018
Erfassung von Teilentladungen an polymerisolierten Kabeln bei der Vor-Ort-Prüfung und im Netzbetrieb
U Schichler
Shaker, 1996
111996
Review of CIGRE TB 496 regarding prequalification Test on Extruded MVDC cables
A Buchner, U Schichler
Proceedings of the Nordic Insulation Symposium, 2019
102019
Basic phenomena in gas-insulated HVDC systems and adequate dielectric testing
C Neumann, K Juhre, U Riechert, U Schichler
CIGRE-IEC Conference on EHV and UHV (AC & DC), Hakodate, 23-26, 2019
102019
The system can't perform the operation now. Try again later.
Articles 1–20