Folgen
Georg Ramer
Georg Ramer
TU Wien, Institute for Chemical Technologies and Analytics
Bestätigte E-Mail-Adresse bei tuwien.ac.at
Titel
Zitiert von
Zitiert von
Jahr
On the Identification of Rayon/Viscose as a Major Fraction of Microplastics in the Marine Environment: Discrimination between Natural and Manmade Cellulosic Fibers Using …
IR Comnea-Stancu, K Wieland, G Ramer, A Schwaighofer, B Lendl
Applied Spectroscopy 71 (5), 939-950, 2017
1642017
Nanophotonic atomic force microscope transducers enable chemical composition and thermal conductivity measurements at the nanoscale
J Chae, S An, G Ramer, V Stavila, G Holland, Y Yoon, AA Talin, ...
Nano letters 17 (9), 5587-5594, 2017
1172017
Determination of polypeptide conformation with nanoscale resolution in water
G Ramer, FS Ruggeri, A Levin, TPJ Knowles, A Centrone
ACS nano 12 (7), 6612-6619, 2018
1062018
Attenuated Total Reflection F ourier Transform Infrared Spectroscopy
G Ramer, B Lendl
Encyclopedia of analytical chemistry: applications, theory and instrumentation, 2006
1002006
External-cavity quantum cascade laser spectroscopy for mid-IR transmission measurements of proteins in aqueous solution
MR Alcaráz, A Schwaighofer, C Kristament, G Ramer, M Brandstetter, ...
Analytical chemistry 87 (13), 6980-6987, 2015
992015
Stand-off Raman spectroscopy: a powerful technique for qualitative and quantitative analysis of inorganic and organic compounds including explosives
B Zachhuber, G Ramer, A Hobro, EH Chrysostom, B Lendl
Analytical and bioanalytical chemistry 400, 2439-2447, 2011
862011
Nanoscale chemical imaging of individual chemotherapeutic cytarabine-loaded liposomal nanocarriers
K Wieland, G Ramer, VU Weiss, G Allmaier, B Lendl, A Centrone
Nano research 12, 197-203, 2019
772019
Quantitative chemical analysis at the nanoscale using the photothermal induced resonance technique
G Ramer, VA Aksyuk, A Centrone
Analytical chemistry 89 (24), 13524-13531, 2017
752017
The next generation of IR spectroscopy: EC-QCL-based mid-IR transmission spectroscopy of proteins with balanced detection
CK Akhgar, G Ramer, M Żbik, A Trajnerowicz, J Pawluczyk, ...
Analytical Chemistry 92 (14), 9901-9907, 2020
712020
Spontaneous current constriction in threshold switching devices
JM Goodwill, G Ramer, D Li, BD Hoskins, G Pavlidis, JJ McClelland, ...
Nature communications 10 (1), 1628, 2019
642019
Revealing the Distribution of Metal Carboxylates in Oil Paint from the Micro‐to Nanoscale
X Ma, V Beltran, G Ramer, G Pavlidis, DY Parkinson, M Thoury, ...
Angewandte Chemie 131 (34), 11778-11782, 2019
352019
Double-layered nanoparticle stacks for surface enhanced infrared absorption spectroscopy
J Srajer, A Schwaighofer, G Ramer, S Rotter, B Guenay, A Kriegner, ...
Nanoscale 6 (1), 127-131, 2014
352014
Fibre optic ATR-IR spectroscopy at cryogenic temperatures: in-line reaction monitoring on organolithium compounds
D Lumpi, C Wagner, M Schöpf, E Horkel, G Ramer, B Lendl, J Fröhlich
Chemical communications 48 (18), 2451-2453, 2012
332012
Implementation of resonance tracking for assuring reliability in resonance enhanced photothermal infrared spectroscopy and imaging
G Ramer, F Reisenbauer, B Steindl, W Tomischko, B Lendl
Applied Spectroscopy 71 (8), 2013-2020, 2017
232017
Spectrally resolved linewidth enhancement factor of a semiconductor frequency comb
N Opačak, F Pilat, D Kazakov, S Dal Cin, G Ramer, B Lendl, F Capasso, ...
Optica 8 (9), 1227-1230, 2021
212021
Method for Time-Resolved Monitoring of a Solid State Biological Film Using Photothermal Infrared Nanoscopy on the Example of Poly-l-lysine
G Ramer, A Balbekova, A Schwaighofer, B Lendl
Analytical chemistry 87 (8), 4415-4420, 2015
192015
Nitrogen-rich compounds of the actinoids: dioxouranium (vi) 5, 5′-azobis [tetrazolide] pentahydrate and its unusually small uranyl angle
G Steinhauser, G Giester, C Wagner, P Weinberger, B Zachhuber, ...
Inorganic Chemistry 51 (12), 6739-6745, 2012
182012
Systematic analysis and nanoscale chemical imaging of polymers using photothermal-induced resonance (AFM-IR) infrared spectroscopy
ACVD dos Santos, B Lendl, G Ramer
Polymer Testing 106, 107443, 2022
162022
Highly biaxially strained silicene on Au (111)
D Nazzari, J Genser, V Ritter, O Bethge, E Bertagnolli, G Ramer, B Lendl, ...
The Journal of Physical Chemistry C 125 (18), 9973-9980, 2021
152021
Polarimetric Balanced Detection: Background-Free Mid-IR Evanescent Field Laser Spectroscopy for Low-Noise, Long-Term Stable Chemical Sensing
S Freitag, M Baer, L Buntzoll, G Ramer, A Schwaighofer, B Schmauss, ...
ACS sensors 6 (1), 35-42, 2020
152020
Das System kann den Vorgang jetzt nicht ausführen. Versuchen Sie es später erneut.
Artikel 1–20