Folgen
Oscar Cota
Oscar Cota
Bestätigte E-Mail-Adresse bei imtek.uni-freiburg.de - Startseite
Titel
Zitiert von
Zitiert von
Jahr
Blood pressure control with selective vagal nerve stimulation and minimal side effects
DTT Plachta, M Gierthmuehlen, O Cota, N Espinosa, F Boeser, ...
Journal of neural engineering 11 (3), 036011, 2014
1842014
Effect of cardiac-cycle-synchronized selective vagal stimulation on heart rate and blood pressure in rats
DTT Plachta, J Zentner, D Aguirre, O Cota, T Stieglitz, M Gierthmuehlen
Advances in therapy 33, 1246-1261, 2016
212016
Detection of baroreceptor activity in rat vagal nerve recording using a multi-channel cuff-electrode and real-time coherent averaging
DTT Plachta, N Espinosa, M Gierthmuehlen, O Cota, TC Herrera, ...
2012 Annual International Conference of the IEEE Engineering in Medicine and …, 2012
192012
BaroLoop: Using a multichannel cuff electrode and selective stimulation to reduce blood pressure
DTT Plachta, M Gierthmuehlen, O Cota, F Boeser, T Stieglitz
2013 35th Annual International Conference of the IEEE Engineering in …, 2013
182013
Embedded device for simultaneous recording and stimulation for retina implant research
M Schlösser, O Cota, R Heil, J Brusius, A Offenhäusser, SV Waasen, ...
SENSORS, 2013 IEEE, 1-4, 2013
112013
In-vivo characterization of a 0.8 – 3 µVRMSinput-noise versatile CMOS pre-amplifier
OF Cota, D Plachta, T Stieglitz, Y Manoli, M Kuhl
2015 7th International IEEE/EMBS Conference on Neural Engineering (NER), 458-461, 2015
82015
Influence of clonidine on antihypertensive selective afferent vagal nerve stimulation in rats
M Gierthmuehlen, D Aguirre, O Cota, J Zentner, T Stieglitz, DTT Plachta
Neuromodulation: Technology at the Neural Interface 19 (6), 597-606, 2016
62016
A virtual workbench for peripheral electrode design
DTT Plachta, J Sonnenfeld, O Cota, T Stieglitz
Automatisierungstechnische Verfahren für die Medizin 17 (286), 62-63, 2012
52012
iNODE in-vivo testing for selective vagus nerve recording and stimulation
OF Cota, M Schlösser, M Schiek, T Stieglitz, M Gierthmuehlen, D Plachta
2015 7th International IEEE/EMBS Conference on Neural Engineering (NER), 525-528, 2015
32015
In vivo characterization of a versatile 8-channel digital biopotential recording system with sub-μVRMSinput noise
OF Cota, D Plachta, T Stieglitz, S Kundumattathil, Y Manoli, M Kuhl
2016 38th Annual International Conference of the IEEE Engineering in …, 2016
12016
Selektive Ableitung und Stimulation für ein blutdrucksenkendes Implantat unter Verwendung von Vielkanal-Cuff-Elektroden
DTT Plachta, O Cota, T Stieglitz, M Gierthmühlen
Oldenbourg Wissenschaftsverlag GmbH 80 (5), 163-172, 2013
12013
Digital biopotential acquisition system having 8 channels
M Kuhl, Y Manoli, D Plachta, T Stieglitz, O Cota
US Patent 11,123,000, 2021
2021
Selective Recording and Stimulation for a Blood Pressure Reducing Implant Using Cuff Electrodes
DTT Plachta, O Cota, T Stieglitz, M Gierthmuehlen
TM-TECHNISCHES MESSEN 80 (5), 163-171, 2013
2013
Selective stimulation of the Vagus Nerve controls the blood pressure and simultaneously avoids significant side effects of Bradycardia and Bradypnea.
DTT Plachta, O Cota, N Espinosa, T Stieglitz, M Gierthmuehlen, ...
10. Workshop Automatisierungstechnische Verfahren für die Medizin vom 29. bis 30. März 2012 in Aachen
DTT Plachta, J Sonnenfeld, O Cota, T Stieglitz, K Radermacher, ...
Das System kann den Vorgang jetzt nicht ausführen. Versuchen Sie es später erneut.
Artikel 1–15