Follow
David Flack
David Flack
Senior Research Scientist, National Physical Laboratory
Verified email at npl.co.uk - Homepage
Title
Cited by
Cited by
Year
Measurement Good Practice Guide No. 43: CMM Probing
D Flack
National Physical Laboratory, London, UK, 2001
58*2001
Measurment good practice guide: CMM measurment strategies
D Flack
National Physical Laboratory (NPL) No 41, 2001
46*2001
CMM measurement strategies
D Flack
National Physical Laboratory, 2001
38*2001
Good Practice Guide No. 42-CMM Verification
D Flack
National Physical Laboratory, 2011
36*2011
Measurement good practice Guide No. 42: CMM verification
D Flack
National Physical Laboratory, 2001
362001
Good Practice Guide No. 41 CMM Measurement Strategies
D Flack
London: Natinal Physical Laboratory, 2014
32*2014
Measurement Good Practice Guide No. 41: CMM Measurement Strategies
D Flack
National Physical Laboratory, London, UK, 2001
322001
Dimensional characterization of a quasispherical resonator by microwave and coordinate measurement techniques
R Underwood, D Flack, P Morantz, G Sutton, P Shore, M de Podesta
Metrologia 48 (1), 1, 2010
302010
Characterization of the volume and shape of quasi-spherical resonators using coordinate measurement machines
M De Podesta, EF May, JB Mehl, L Pitre, RM Gavioso, G Benedetto, ...
Metrologia 47 (5), 588, 2010
292010
Measurement Good Practice Guide No. 42
D Flack, CMM Probing
Callipers and Micrometers. National Physical Laboratory, 2001
292001
A review of industrial capabilities to measure free-form surfaces
G Rodger, D Flack, M McCarthy
National Physical Laboratory, 2007
262007
CMM probing
D Flack
National Physical Laboratory, 2001
222001
CCM key comparison in the pressure range 0.05 MPa to 1 MPa (gas medium, gauge mode). Phase A1: Dimensional measurements and calculation of effective area
GF Molinar, B Rebaglia, A Sacconi, JC Legras, GP Vailleau, JW Schmidt, ...
Metrologia 36 (6), 657, 1999
221999
Co-ordinate measuring machine task-specific measurement uncertainties.
DR Flack
212013
Fundamental good practice in dimensional metrology
D Flack, J Hannaford
National Physical Laboratory, 2005
182005
CMM verification
D Flack
National Physical Laboratory, 2001
18*2001
Development of a new traceable areal surface texture measuring instrument
RK Leach, DR Flack, EB Hughes, CW Jones
Wear 266 (5-6), 552-554, 2009
172009
A comparison of sensitivity standards in form metrology—final results of the EURAMET project 649
O Jusko, H Bosse, D Flack, B Hemming, M Pisani, R Thalmann
Measurement Science and Technology 23 (5), 054006, 2012
152012
Measurement Good Practice Guide No. 80: Fundamental Good Practice in Dimensional Metrology
D Flack, J Hannaford
National Physical Laboratory, Hampton Road, Teddington, Middlesex, 2005
152005
Microsystems technology standardisation roadmap.
RK Leach, Z Cui, DR Flack
NPL, UK, 2003
132003
The system can't perform the operation now. Try again later.
Articles 1–20