Follow
Bart Kaptein
Bart Kaptein
Senior researcher Dept. of Orthopaedics, Leiden University Medical Center
Verified email at lumc.nl
Title
Cited by
Cited by
Year
A new model-based RSA method validated using CAD models and models from reversed engineering
BL Kaptein, ER Valstar, BC Stoel, PM Rozing, JHC Reiber
Journal of biomechanics 36 (6), 873-882, 2003
2952003
2D–3D shape reconstruction of the distal femur from stereo X-ray imaging using statistical shape models
N Baka, BL Kaptein, M de Bruijne, T van Walsum, JE Giphart, WJ Niessen, ...
Medical image analysis 15 (6), 840-850, 2011
2162011
Soft-tissue artefact assessment during step-up using fluoroscopy and skin-mounted markers
EH Garling, BL Kaptein, B Mertens, W Barendregt, HEJ Veeger, ...
Journal of biomechanics 40, S18-S24, 2007
1342007
Clinical validation of model-based RSA for a total knee prosthesis
BL Kaptein, ER Valstar, BC Stoel, HC Reiber, RG Nelissen
Clinical Orthopaedics and Related Research® 464, 205-209, 2007
1252007
Cemented versus cementless Oxford unicompartmental knee arthroplasty using radiostereometric analysis: a randomised controlled trial
BJL Kendrick, BL Kaptein, ER Valstar, HS Gill, WFM Jackson, CAF Dodd, ...
The bone & joint journal 97 (2), 185-191, 2015
1072015
Development and experimental validation of a three-dimensional finite element model of the human scapula
S Gupta, FCT Van Der Helm, JC Sterk, F Van Keulen, BL Kaptein
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2004
1052004
Good diagnostic performance of early migration as a predictor of late aseptic loosening of acetabular cups: results from ten years of follow-up with Roentgen …
MJ Nieuwenhuijse, ER Valstar, BL Kaptein, RGHH Nelissen
JBJS 94 (10), 874-880, 2012
1002012
Marker configuration model-based roentgen fluoroscopic analysis
EH Garling, BL Kaptein, K Geleijns, RGHH Nelissen, ER Valstar
Journal of Biomechanics 38 (4), 893-901, 2005
882005
Model-based RSA of a femoral hip stem using surface and geometrical shape models
BL Kaptein, ER Valstar, CW Spoor, BC Stoel, PM Rozing
Clinical Orthopaedics and Related Research® 448, 92-97, 2006
872006
Polyethylene wear of mobile-bearing unicompartmental knee replacement at 20 years
BJL Kendrick, DJ Simpson, BL Kaptein, ER Valstar, HS Gill, DW Murray, ...
The Journal of Bone & Joint Surgery British Volume 93 (4), 470-475, 2011
842011
Evaluation of three pose estimation algorithms for model-based roentgen stereophotogrammetric analysis
BL Kaptein, E R Valstar, BC Stoel, PM Rozing, JHC Reiber
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2004
762004
Comparison of the model-based and marker-based roentgen stereophotogrammetry methods in a typical clinical setting
C Hurschler, F Seehaus, J Emmerich, BL Kaptein, H Windhagen
The Journal of arthroplasty 24 (4), 594-606, 2009
722009
Image-based RSA: Roentgen stereophotogrammetric analysis based on 2D–3D image registration
PW De Bruin, BL Kaptein, BC Stoel, JHC Reiber, PM Rozing, ER Valstar
Journal of biomechanics 41 (1), 155-164, 2008
642008
The Exeter femoral stem continues to migrate during its first decade after implantation: 10–12 years of follow-up with radiostereometric analysis (RSA)
MJ Nieuwenhuijse, ER Valstar, BL Kaptein, RGHH Nelissen
Acta orthopaedica 83 (2), 129-134, 2012
632012
A new type of model-based Roentgen stereophotogrammetric analysis for solving the occluded marker problem
BL Kaptein, ER Valstar, BC Stoel, PM Rozing, JHC Reiber
Journal of biomechanics 38 (11), 2330-2334, 2005
602005
Migration of a novel 3D-printed cementless versus a cemented total knee arthroplasty: two-year results of a randomized controlled trial using radiostereometric analysis
S Hasan, KT van Hamersveld, PJ Marang-van de Mheen, BL Kaptein, ...
The bone & joint journal 102 (8), 1016-1024, 2020
532020
Estimating muscle attachment contours by transforming geometrical bone models
BL Kaptein, FCT Van der Helm
Journal of Biomechanics 37 (3), 263-273, 2004
522004
The beneficial effect of hydroxyapatite lasts: a randomized radiostereometric trial comparing hydroxyapatite-coated, uncoated, and cemented tibial components for up to 16 years
BG Pijls, ER Valstar, BL Kaptein, M Fiocco, RGHH Nelissen
Acta orthopaedica 83 (2), 135-141, 2012
492012
Limited rotation of the mobile-bearing in a rotating platform total knee prosthesis
EH Garling, BL Kaptein, RGHH Nelissen, ER Valstar
Journal of biomechanics 40, S25-S30, 2007
482007
The stability of fixation of proximal femoral fractures: a radiostereometric analysis
D Van Embden, GANL Stollenwerck, LA Koster, BL Kaptein, R Nelissen, ...
The Bone & Joint Journal 97 (3), 391-397, 2015
462015
The system can't perform the operation now. Try again later.
Articles 1–20