Ion mobility spectrometer with orthogonal X-ray source for increased sensitivity E Bunert, T Reinecke, AT Kirk, A Bohnhorst, S Zimmermann Talanta 185, 537-541, 2018 | 21 | 2018 |
Shutterless ion mobility spectrometer with fast pulsed electron source E Bunert, A Heptner, T Reinecke, AT Kirk, S Zimmermann Review of Scientific Instruments 88 (2), 2017 | 20 | 2017 |
Fast pulsed operation of a small non-radioactive electron source with continuous emission current control P Cochems, AT Kirk, E Bunert, M Runge, P Goncalves, S Zimmermann Review of Scientific Instruments 86 (6), 2015 | 18 | 2015 |
Comparison of spatial ion distributions from different ionization sources E Bunert, AT Kirk, O Käbein, S Zimmermann International Journal for Ion Mobility Spectrometry 22, 21-29, 2019 | 12 | 2019 |
Improving the analytical performance of ion mobility spectrometer using a non-radioactive electron source A Heptner, N Angerstein, T Reinecke, E Bunert, AT Kirk, I Niedzwiecki, ... International Journal for Ion Mobility Spectrometry 19, 175-182, 2016 | 10 | 2016 |
Electron capture detector with non-radioactive electron source E Bunert, AT Kirk, J Oermann, S Zimmermann Proceedings 1 (1), 443, 2017 | 6 | 2017 |
Non-radioactive electron capture detector for gas chromatography—A possible replacement for radioactive detectors E Bunert, B Bernhold, JN Woidtke, M Sehlmeyer, S Zimmermann Journal of Chromatography A 1606, 460384, 2019 | 5 | 2019 |
Electron capture detector based on a non-radioactive electron source: operating parameters vs. analytical performance E Bunert, AT Kirk, J Oermann, S Zimmermann Journal of Sensors and Sensor Systems 6 (2), 381-387, 2017 | 5 | 2017 |
Non-radioactive electron source with nanosecond pulse modulation for atmospheric pressure chemical ionization E Bunert, M Berger, AT Kirk, S Zimmermann Review of Scientific Instruments 90 (11), 2019 | 3 | 2019 |
An Electron Capture Detector Based on a Non-Radioactive Electron Source E Bunert, AT Kirk, J Oermann, S Zimmermann Proceedings of the AMA Conferences, 2017 | 3 | 2017 |
2.4-Application of a New Non-Radioactive Field Emission based Electron Source in Electron Capture Detectors C Wendt, E Bunert, S Zimmermann, M Bachmann, F Düsberg, S Edler, ... Tagungsband, 40-43, 2019 | 2 | 2019 |
Electron capture detector based on X-ray ionization MJ Kueddelsmann, E Bunert, S Zimmermann tm-Technisches Messen 89 (s1), 72-76, 2022 | 1 | 2022 |
Silicon field emitter arrays produced via wafer dicing A Kusch, M Wurz, E Bunert, S Zimmermann 2017 30th International Vacuum Nanoelectronics Conference (IVNC), 132-133, 2017 | 1 | 2017 |
Pulsed electron source for atmospheric pressure chemical ionization in ion mobility spectrometry E Bunert, A Heptner, AT Kirk, O Käbein, S Zimmermann, A Kusch, ... 2017 30th International Vacuum Nanoelectronics Conference (IVNC), 102-103, 2017 | 1 | 2017 |
Non-radioactive electron capture detector based on soft X-ray ionization for gas chromatography-A possible replacement for radioactive detectors MJ Kueddelsmann, JJ Stadtler, AT Kirk, E Bunert, S Zimmermann Journal of Chromatography A 1711, 464453, 2023 | | 2023 |
Ionization Detector and Detection Method M Bachmann, A Schels, F Herdl, S Zimmermann, S Edler, E Bunert US Patent App. 18/316,194, 2023 | | 2023 |
P8. 8-Electron Capture Detector Based on X-rays N Solle, E Bunert, S Zimmermann Poster, 281-284, 2021 | | 2021 |
Non-radioactive electron emitter as ionization source for electron capture detectors and ion mobility spectrometry E Bunert | | 2021 |
Novel Non-Radiative Electron Source F Düsberg, M Bachmann, S Edler, A Pahlke, C Langer, C Prommesberger, ... | | 2019 |
Brandfrüherkennung mit einem neuartigen Ionen-Mobilitäts-Spektrometer mit nicht-radioaktiver Quelle zur Verbesserung der Sicherheit: Teilvorhaben: Untersuchung einer … E Bunert, S Zimmermann Leibniz Universität Hannover, Institut für Grundlagen der Elektrotechnik und …, 2016 | | 2016 |