Folgen
Dr.-Ing. Erik Bunert
Dr.-Ing. Erik Bunert
Sonstige NamenErik Bunert, E. Bunert, Bunert, E.
Bestätigte E-Mail-Adresse bei geml.uni-hannover.de - Startseite
Titel
Zitiert von
Zitiert von
Jahr
Ion mobility spectrometer with orthogonal X-ray source for increased sensitivity
E Bunert, T Reinecke, AT Kirk, A Bohnhorst, S Zimmermann
Talanta 185, 537-541, 2018
212018
Shutterless ion mobility spectrometer with fast pulsed electron source
E Bunert, A Heptner, T Reinecke, AT Kirk, S Zimmermann
Review of Scientific Instruments 88 (2), 2017
202017
Fast pulsed operation of a small non-radioactive electron source with continuous emission current control
P Cochems, AT Kirk, E Bunert, M Runge, P Goncalves, S Zimmermann
Review of Scientific Instruments 86 (6), 2015
182015
Comparison of spatial ion distributions from different ionization sources
E Bunert, AT Kirk, O Käbein, S Zimmermann
International Journal for Ion Mobility Spectrometry 22, 21-29, 2019
122019
Improving the analytical performance of ion mobility spectrometer using a non-radioactive electron source
A Heptner, N Angerstein, T Reinecke, E Bunert, AT Kirk, I Niedzwiecki, ...
International Journal for Ion Mobility Spectrometry 19, 175-182, 2016
102016
Electron capture detector with non-radioactive electron source
E Bunert, AT Kirk, J Oermann, S Zimmermann
Proceedings 1 (1), 443, 2017
62017
Non-radioactive electron capture detector for gas chromatography—A possible replacement for radioactive detectors
E Bunert, B Bernhold, JN Woidtke, M Sehlmeyer, S Zimmermann
Journal of Chromatography A 1606, 460384, 2019
52019
Electron capture detector based on a non-radioactive electron source: operating parameters vs. analytical performance
E Bunert, AT Kirk, J Oermann, S Zimmermann
Journal of Sensors and Sensor Systems 6 (2), 381-387, 2017
52017
Non-radioactive electron source with nanosecond pulse modulation for atmospheric pressure chemical ionization
E Bunert, M Berger, AT Kirk, S Zimmermann
Review of Scientific Instruments 90 (11), 2019
32019
An Electron Capture Detector Based on a Non-Radioactive Electron Source
E Bunert, AT Kirk, J Oermann, S Zimmermann
Proceedings of the AMA Conferences, 2017
32017
2.4-Application of a New Non-Radioactive Field Emission based Electron Source in Electron Capture Detectors
C Wendt, E Bunert, S Zimmermann, M Bachmann, F Düsberg, S Edler, ...
Tagungsband, 40-43, 2019
22019
Electron capture detector based on X-ray ionization
MJ Kueddelsmann, E Bunert, S Zimmermann
tm-Technisches Messen 89 (s1), 72-76, 2022
12022
Silicon field emitter arrays produced via wafer dicing
A Kusch, M Wurz, E Bunert, S Zimmermann
2017 30th International Vacuum Nanoelectronics Conference (IVNC), 132-133, 2017
12017
Pulsed electron source for atmospheric pressure chemical ionization in ion mobility spectrometry
E Bunert, A Heptner, AT Kirk, O Käbein, S Zimmermann, A Kusch, ...
2017 30th International Vacuum Nanoelectronics Conference (IVNC), 102-103, 2017
12017
Non-radioactive electron capture detector based on soft X-ray ionization for gas chromatography-A possible replacement for radioactive detectors
MJ Kueddelsmann, JJ Stadtler, AT Kirk, E Bunert, S Zimmermann
Journal of Chromatography A 1711, 464453, 2023
2023
Ionization Detector and Detection Method
M Bachmann, A Schels, F Herdl, S Zimmermann, S Edler, E Bunert
US Patent App. 18/316,194, 2023
2023
P8. 8-Electron Capture Detector Based on X-rays
N Solle, E Bunert, S Zimmermann
Poster, 281-284, 2021
2021
Non-radioactive electron emitter as ionization source for electron capture detectors and ion mobility spectrometry
E Bunert
2021
Novel Non-Radiative Electron Source
F Düsberg, M Bachmann, S Edler, A Pahlke, C Langer, C Prommesberger, ...
2019
Brandfrüherkennung mit einem neuartigen Ionen-Mobilitäts-Spektrometer mit nicht-radioaktiver Quelle zur Verbesserung der Sicherheit: Teilvorhaben: Untersuchung einer …
E Bunert, S Zimmermann
Leibniz Universität Hannover, Institut für Grundlagen der Elektrotechnik und …, 2016
2016
Das System kann den Vorgang jetzt nicht ausführen. Versuchen Sie es später erneut.
Artikel 1–20