Folgen
Anastasios Petrou
Anastasios Petrou
Bestätigte E-Mail-Adresse bei alumni.ethz.ch
Titel
Zitiert von
Zitiert von
Jahr
A Soft Total Artificial Heart—First Concept Evaluation on a Hybrid Mock Circulation
NH Cohrs, A Petrou, M Loepfe, M Yliruka, CM Schumacher, AX Kohll, ...
Artificial organs 41 (10), 948-958, 2017
1012017
Standardized Comparison of Selected Physiological Controllers for Rotary Blood Pumps: In Vitro Study
A Petrou, J Lee, S Dual, G Ochsner, M Meboldt, M Schmid Daners
Artificial organs 42 (3), E29-E42, 2018
652018
In Vivo Evaluation of Physiologic Control Algorithms for Left Ventricular Assist Devices Based on Left Ventricular Volume or Pressure
G Ochsner, MJ Wilhelm, R Amacher, A Petrou, N Cesarovic, S Staufert, ...
ASAIO journal 63 (5), 568-577, 2017
562017
Virtual surgical planning, flow simulation and 3D electro-spinning of patient-specific grafts to optimize Fontan hemodynamics
D Siallagan, YH Loke, L Olivieri, J Opfermann, CS Ong, D de Zélicourt, ...
The Journal of Thoracic and Cardiovascular Surgery, 2017
46*2017
A Novel Multi-objective Physiological Control System for Rotary Left Ventricular Assist Devices
A Petrou, M Monn, M Meboldt, MS Daners
Annals of biomedical engineering 45 (12), 2899-2910, 2017
442017
Control of the fluid viscosity in a mock circulation
S Boës, G Ochsner, R Amacher, A Petrou, M Meboldt, M Schmid Daners
Artificial organs 42 (1), 68-77, 2018
402018
A physiological controller for turbodynamic ventricular assist devices based on left ventricular systolic pressure
A Petrou, G Ochsner, R Amacher, P Pergantis, M Rebholz, M Meboldt, ...
Artificial organs 40 (9), 842-855, 2016
392016
A versatile hybrid mock circulation for hydraulic investigations of active and passive cardiovascular implants
A Petrou, M Granegger, M Meboldt, MS Daners
Asaio Journal 65 (5), 495, 2019
382019
Comparison of Flow Estimators for Rotary Blood Pumps: An In Vitro and In Vivo Study
A Petrou, D Kuster, J Lee, M Meboldt, MS Daners
Annals of biomedical engineering 46 (12), 2123-2134, 2018
192018
Viscosity Prediction in a Physiologically Controlled Ventricular Assist Device
A Petrou, M Kanakis, S Boes, P Pergantis, M Meboldt, MS Daners
IEEE Transactions on Biomedical Engineering, 2018
142018
High-frequency operation of a pulsatile VAD–a simulation study
M Rebholz, R Amacher, A Petrou, M Meboldt, MS Daners
Biomedical Engineering/Biomedizinische Technik 62 (2), 161-170, 2017
142017
Long-Term Performance of a Pneumatically Actuated Soft Pump Manufactured by Rubber Compression Molding
AX Kohll, NH Cohrs, R Walker, A Petrou, M Loepfe, M Schmid Daners, ...
Soft robotics 6 (2), 206-213, 2019
122019
Biomedical apparatus with a pressure-regulated blood pump
G Ochsner, MS Daners, R Amacher, M Meboldt, V Falk, A Petrou, ...
US Patent 11,045,640, 2021
92021
Cardiac Output Estimation: Online Implementation for Left Ventricular Assist Device Support
A Petrou, M Kanakis, K Magkoutas, B De Vries, M Meboldt, MS Daners
IEEE Transactions on Biomedical Engineering 68 (6), 1990-1998, 2020
92020
R-wave magnitude: a control input for ventricular assist devices
SA Dual, G Ochsner, A Petrou, R Amacher, MJ Wilhelm, M Meboldt, ...
Proceedings of the 8th International Workshop on Biosignal Interpretation, 18-21, 2016
82016
Response of a physiological controller for ventricular assist devices during acute patho-physiological events: an in vitro study
A Petrou, P Pergantis, G Ochsner, R Amacher, T Krabatsch, V Falk, ...
Biomedical Engineering/Biomedizinische Technik 62 (6), 623-633, 2017
72017
Intelligent Rotary Blood Pumps with Physiological Response
A Petrou
ETH Zurich, 2018
12018
Correction to: Comparison of Flow Estimators for Rotary Blood Pumps: An In Vitro and In Vivo Study
A Petrou, D Kuster, J Lee, M Meboldt, MS Daners
Annals of biomedical engineering 47 (8), 1827-1827, 2019
2019
Das System kann den Vorgang jetzt nicht ausführen. Versuchen Sie es später erneut.
Artikel 1–18