Nate Kaiser
Nate Kaiser
Biodesix
Bestätigte E-Mail-Adresse bei magnet.fsu.edu
Titel
Zitiert von
Zitiert von
Jahr
A novel 9.4 Tesla FTICR mass spectrometer with improved sensitivity, mass resolution, and mass range
NK Kaiser, JP Quinn, GT Blakney, CL Hendrickson, AG Marshall
Journal of the American Society for Mass Spectrometry 22 (8), 1343-1351, 2011
2032011
Parts-per-billion Fourier transform ion cyclotron resonance mass measurement accuracy with a “walking” calibration equation
JJ Savory, NK Kaiser, AM McKenna, F Xian, GT Blakney, RP Rodgers, ...
Analytical chemistry 83 (5), 1732-1736, 2011
1592011
The Smallest Stable Fullerene, M@C28 (M = Ti, Zr, U): Stabilization and Growth from Carbon Vapor
PW Dunk, NK Kaiser, M Mulet-Gas, A Rodríguez-Fortea, JM Poblet, ...
Journal of the American Chemical Society 134 (22), 9380-9389, 2012
1472012
Closed network growth of fullerenes
PW Dunk, NK Kaiser, CL Hendrickson, JP Quinn, CP Ewels, Y Nakanishi, ...
Nature communications 3 (1), 1-9, 2012
1382012
21 Tesla Fourier transform ion cyclotron resonance mass spectrometer: a national resource for ultrahigh resolution mass analysis
CL Hendrickson, JP Quinn, NK Kaiser, DF Smith, GT Blakney, T Chen, ...
Journal of the American Society for Mass Spectrometry 26 (9), 1626-1632, 2015
1282015
Expansion of the analytical window for oil spill characterization by ultrahigh resolution mass spectrometry: beyond gas chromatography
AM McKenna, RK Nelson, CM Reddy, JJ Savory, NK Kaiser, ...
Environmental science & technology 47 (13), 7530-7539, 2013
1242013
Electrically compensated Fourier transform ion cyclotron resonance cell for complex mixture mass analysis
NK Kaiser, JJ Savory, AM McKenna, JP Quinn, CL Hendrickson, ...
Analytical chemistry 83 (17), 6907-6910, 2011
1052011
Unprecedented ultrahigh resolution FT-ICR mass spectrometry and parts-per-billion mass accuracy enable direct characterization of nickel and vanadyl porphyrins in petroleum …
AM McKenna, JT Williams, JC Putman, C Aeppli, CM Reddy, ...
Energy & fuels 28 (4), 2454-2464, 2014
772014
Identification and characterization of human proteoforms by top-down LC-21 tesla FT-ICR mass spectrometry
LC Anderson, CJ DeHart, NK Kaiser, RT Fellers, DF Smith, JB Greer, ...
Journal of proteome research 16 (2), 1087-1096, 2017
652017
Unit mass baseline resolution for an intact 148 kDa therapeutic monoclonal antibody by Fourier transform ion cyclotron resonance mass spectrometry
SG Valeja, NK Kaiser, F Xian, CL Hendrickson, JC Rouse, AG Marshall
Analytical chemistry 83 (22), 8391-8395, 2011
632011
Bottom-up formation of endohedral mono-metallofullerenes is directed by charge transfer
PW Dunk, M Mulet-Gas, Y Nakanishi, NK Kaiser, A Rodríguez-Fortea, ...
Nature communications 5 (1), 1-8, 2014
612014
Incorporation of a flared inlet capillary tube on a fourier transform ion cyclotron resonance mass spectrometer
S Wu, K Zhang, NK Kaiser, JE Bruce, DC Prior, GA Anderson
Journal of the American Society for Mass Spectrometry 17 (6), 772-779, 2006
612006
A photocleavable and mass spectrometry identifiable cross-linker for protein interaction studies
L Yang, X Tang, CR Weisbrod, GR Munske, JK Eng, PD von Haller, ...
Analytical chemistry 82 (9), 3556-3566, 2010
602010
Metallofullerene and fullerene formation from condensing carbon gas under conditions of stellar outflows and implication to stardust
PW Dunk, JJ Adjizian, NK Kaiser, JP Quinn, GT Blakney, CP Ewels, ...
Proceedings of the National Academy of Sciences 110 (45), 18081-18086, 2013
472013
Mass resolution and mass accuracy: how much is enough?
AG Marshall, GT Blakney, T Chen, NK Kaiser, AM McKenna, RP Rodgers, ...
Mass spectrometry 2 (Special_Issue), S0009-S0009, 2013
312013
Front-end electron transfer dissociation coupled to a 21 Tesla FT-ICR mass spectrometer for intact protein sequence analysis
CR Weisbrod, NK Kaiser, JEP Syka, L Early, C Mullen, JJ Dunyach, ...
Journal of the American Society for Mass Spectrometry 28 (9), 1787-1795, 2017
292017
Tailored ion radius distribution for increased dynamic range in FT-ICR mass analysis of complex mixtures
NK Kaiser, AM McKenna, JJ Savory, CL Hendrickson, AG Marshall
Analytical chemistry 85 (1), 265-272, 2013
292013
Controlled Ion Ejection from an External Trap for Extended m/z Range in FT-ICR Mass Spectrometry
NK Kaiser, JJ Savory, CL Hendrickson
Journal of The American Society for Mass Spectrometry 25 (6), 943-949, 2014
282014
A bifunctional monolithic column for combined protein preconcentration and digestion for high throughput proteomics research
K Zhang, S Wu, X Tang, NK Kaiser, JE Bruce
Journal of Chromatography B 849 (1-2), 223-230, 2007
282007
Formation of Heterofullerenes by Direct Exposure of C60 to Boron Vapor
PW Dunk, A Rodríguez‐Fortea, NK Kaiser, H Shinohara, JM Poblet, ...
Angewandte Chemie 125 (1), 333-337, 2013
242013
Das System kann den Vorgang jetzt nicht ausführen. Versuchen Sie es später erneut.
Artikel 1–20