Scale-space anisotropic total variation for limited angle tomography Y Huang, O Taubmann, X Huang, V Haase, G Lauritsch, A Maier IEEE Transactions on Radiation and Plasma Medical Sciences 2 (4), 307-314, 2018 | 48 | 2018 |
Restoration of missing data in limited angle tomography based on Helgason–Ludwig consistency conditions Y Huang, X Huang, O Taubmann, Y Xia, V Haase, J Hornegger, ... Biomedical Physics & Engineering Express 3 (3), 035015, 2017 | 44 | 2017 |
A new weighted anisotropic total variation algorithm for limited angle tomography Y Huang, O Taubmann, X Huang, V Haase, G Lauritsch, A Maier 2016 IEEE 13th international symposium on biomedical imaging (ISBI), 585-588, 2016 | 28 | 2016 |
Assessing cardiac function from total-variation-regularized 4D C-arm CT in the presence of angular undersampling O Taubmann, V Haase, G Lauritsch, Y Zheng, G Krings, J Hornegger, ... Physics in Medicine & Biology 62 (7), 2762, 2017 | 11 | 2017 |
Image quality analysis of limited angle tomography using the shift-variant data loss model Y Huang, G Lauritsch, M Amrehn, O Taubmann, V Haase, D Stromer, ... Bildverarbeitung für die Medizin 2016: Algorithmen–Systeme–Anwendungen, 277-282, 2016 | 11 | 2016 |
Impact of the non‐negativity constraint in model‐based iterative reconstruction from CT data V Haase, K Hahn, H Schöndube, K Stierstorfer, A Maier, F Noo Medical physics 46 (12), e835-e854, 2019 | 8 | 2019 |
A new scale space total variation algorithm for limited angle tomography Y Huang, O Taubmann, X Huang, V Haase, G Lauritsch, A Maier Proceedings of the 4th International Meeting on Image Formation in X-Ray …, 2016 | 8 | 2016 |
Single‐material beam hardening correction via an analytical energy response model for diagnostic CT V Haase, K Hahn, H Schöndube, K Stierstorfer, A Maier, F Noo Medical physics 49 (8), 5014-5037, 2022 | 5 | 2022 |
Make the Most of Time Temporal Extension of the iTV Algorithm for 4D Cardiac C-Arm CT V Haase, O Taubmann, Y Huang, G Krings, G Lauritsch, A Maier, ... Bildverarbeitung für die Medizin 2016: Algorithmen–Systeme–Anwendungen, 170-175, 2016 | 4 | 2016 |
Reproducibility in dual energy CT: the impact of a projection domain material decomposition method V Haase, F Noo, K Stierstorfer, A Maier, M McNitt-Gray 7th International Conference on Image Formation in X-Ray Computed Tomography …, 2022 | 2 | 2022 |
Single material beam hardening correction in CT using an analytical energy response model V Haase, K Hahn, H Schöndube, K Stierstorfer, A Maier, F Noo 2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC …, 2020 | 2 | 2020 |
An improved combination of ordered subsets and momentum for fast model-based iterative CT reconstruction V Haase, K Stierstorfer, K Hahn, H Schöndube, A Maier, F Noo Medical Imaging 2020: Physics of Medical Imaging 11312, 391-397, 2020 | 2 | 2020 |
Exploring the space between smoothed and non-smooth total variation for 3D iterative CT reconstruction V Haase, K Stierstorfer, K Hahn, H Schöndube, A Maier, F Noo Medical Imaging 2019: Physics of Medical Imaging 10948, 511-517, 2019 | 2 | 2019 |
Penalized least-square CT reconstruction without and with statistical weights: effect on lesion detection performance with human observers V Haase, A Griffith, Z Guo, MB Oktay, K Hahn, H Schoendube, ... Proceedings of the 14th International Meeting on Fully Three-dimensional …, 2017 | 2 | 2017 |
Image reconstruction from real dual energy CT data using an analytical energy response model V Haase, K Hahn, H Schöndube, K Stierstorfer, A Maier, F Noo 2021 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC …, 2021 | 1 | 2021 |
Estimation of statistical weights for model-based iterative CT reconstruction V Haase, K Stierstorfer, K Hahn, H Schöndube, A Maier, F Noo Medical Imaging 2021: Physics of Medical Imaging 11595, 957-962, 2021 | 1 | 2021 |
Artifact Reduction in Interventional Devices Using Virtual Monoenergetic Images and Iterative Metal Artifact Reduction on Photon-Counting Detector CT YC Layer, S Faby, V Haase, B Schmidt, N Mesropyan, PA Kupczyk, ... Investigative Radiology, 10.1097, 2024 | | 2024 |
A study on the accuracy of polynomial fitting for direct computation of material lengths from projection data in dual energy CT V Haase, K Stierstorfer, A Maier, F Noo Medical Imaging 2023: Physics of Medical Imaging 12463, 790-795, 2023 | | 2023 |
Towards enabling better evaluation of emphysema: investigation into a method to reduce the variability of lung CT attenuation values due to patient size and positioning V Haase, F Noo, K Stierstorfer, M McNitt-Gray Medical Imaging 2022: Physics of Medical Imaging 12031, 288-292, 2022 | | 2022 |
On the Value of the Non-negativity Constraint in CT V Haase, K Hahn, H Schöndube, K Stierstorfer, A Maier, F Noo 2019 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC …, 2019 | | 2019 |