Ultra-high-resolution ion mobility separations over extended path lengths and mobility ranges achieved using a multilevel structures for lossless ion manipulations module AL Hollerbach, A Li, A Prabhakaran, G Nagy, CP Harrilal, CR Conant, ... Analytical chemistry 92 (11), 7972-7979, 2020 | 68 | 2020 |
Melting proteins confined in nanodroplets with 10.6 μm light provides clues about early steps of denaturation TJ El-Baba, DR Fuller, DW Woodall, SA Raab, CR Conant, JM Dilger, ... Chemical Communications 54 (26), 3270-3273, 2018 | 42 | 2018 |
Assessing collision cross section calibration strategies for traveling wave-based ion mobility separations in structures for lossless ion manipulations A Li, CR Conant, X Zheng, KJ Bloodsworth, DJ Orton, SVB Garimella, ... Analytical chemistry 92 (22), 14976-14982, 2020 | 34 | 2020 |
Conformationally regulated peptide bond cleavage in bradykinin DR Fuller, CR Conant, TJ El-Baba, CJ Brown, DW Woodall, DH Russell, ... Journal of the American Chemical Society 140 (30), 9357-9360, 2018 | 28 | 2018 |
Rapid and simultaneous characterization of drug conjugation in heavy and light chains of a monoclonal antibody revealed by high-resolution ion mobility separations in SLIM G Nagy, IK Attah, CR Conant, W Liu, SVB Garimella, HP Gunawardena, ... Analytical chemistry 92 (7), 5004-5012, 2020 | 27 | 2020 |
Measurement and theory of gas-phase ion mobility shifts resulting from isotopomer mass distribution changes CP Harrilal, VD Gandhi, G Nagy, X Chen, MG Buchanan, R Wojcik, ... Analytical chemistry 93 (45), 14966-14975, 2021 | 25 | 2021 |
AutoCCS: automated collision cross-section calculation software for ion mobility spectrometry–mass spectrometry JY Lee, A Bilbao, CR Conant, KJ Bloodsworth, DJ Orton, M Zhou, ... Bioinformatics 37 (22), 4193-4201, 2021 | 17 | 2021 |
Dynamic time-warping correction for shifts in ultrahigh resolving power ion mobility spectrometry and structures for lossless ion manipulations AL Hollerbach, CR Conant, G Nagy, ME Monroe, K Gupta, M Donor, ... Journal of the American Society for Mass Spectrometry 32 (4), 996-1007, 2021 | 17 | 2021 |
Ion mobility spectrometer and method of operating same DE Clemmer, MA Ewing, SM Zucker, CRP Conant US Patent 8,872,102, 2014 | 17 | 2014 |
Selected overtone mobility spectrometry MA Ewing, CRP Conant, SM Zucker, KJ Griffith, DE Clemmer Analytical chemistry 87 (10), 5132-5138, 2015 | 16 | 2015 |
Ion mobility spectrometry with high ion utilization efficiency using traveling wave-based structures for lossless ion manipulations A Li, G Nagy, CR Conant, RV Norheim, JY Lee, C Giberson, ... Analytical chemistry 92 (22), 14930-14938, 2020 | 14 | 2020 |
Substance P in solution: trans-to-cis configurational changes of penultimate prolines initiate non-enzymatic peptide bond cleavages CR Conant, DR Fuller, TJ El-Baba, Z Zhang, DH Russell, DE Clemmer Journal of The American Society for Mass Spectrometry 30 (6), 919-931, 2019 | 14 | 2019 |
Substance P in the gas phase: conformational changes and dissociations induced by collisional activation in a drift tube CR Conant, DR Fuller, Z Zhang, DW Woodall, DH Russell, DE Clemmer Journal of The American Society for Mass Spectrometry 30 (6), 932-945, 2019 | 13 | 2019 |
B.; Gunawardena, HP; Shaw, JB; Smith, RD; Ibrahim, YM G Nagy, IK Attah, CR Conant, W Liu, SV Garimella Anal. Chem 92 (7), 5004-5012, 2020 | 11 | 2020 |
Evaluation of waveform profiles for traveling wave ion mobility separations in structures for lossless ion manipulations CR Conant, IK Attah, SVB Garimella, G Nagy, A Bilbao, RD Smith, ... Journal of the American Society for Mass Spectrometry 32 (1), 225-236, 2020 | 10 | 2020 |
Monitoring the stabilities of a mixture of peptides by mass-spectrometry-based techniques DR Fuller, CR Conant, TJ El-Baba, Z Zhang, KR Molloy, CS Zhang, ... European Journal of Mass Spectrometry 25 (1), 73-81, 2019 | 4 | 2019 |
Diketopiperazine Formation from FPGnK (n = 1–9) Peptides: Rates of Structural Rearrangements and Mechanisms Z Zhang, CR Conant, TJ El-Baba, SA Raab, DR Fuller, DA Hales, ... The Journal of Physical Chemistry B 125 (29), 8107-8116, 2021 | 3 | 2021 |
Implementation of ion mobility spectrometry-based separations in structures for lossless ion manipulations (SLIM) AL Hollerbach, CR Conant, G Nagy, YM Ibrahim Biomedical Engineering Technologies: Volume 2, 453-469, 2022 | 2 | 2022 |
Ion mobility spectrometer and method of operating same DE Clemmer, MA Ewing, SM Zucker, CRP Conant US Patent 9,368,333, 2016 | 2 | 2016 |
Ion mobility spectrometer and method of operating same DE Clemmer, MA Ewing, SM Zucker, CRP Conant US Patent 9,129,782, 2015 | 2 | 2015 |