Folgen
Bo Liang
Bo Liang
Research Fellow, Biomedical Engineering, Zhejiang University
Bestätigte E-Mail-Adresse bei zju.edu.cn
Titel
Zitiert von
Zitiert von
Jahr
Direct electron transfer glucose biosensor based on glucose oxidase self-assembled on electrochemically reduced carboxyl graphene
B Liang, L Fang, G Yang, Y Hu, X Guo, X Ye
Biosensors and Bioelectronics 43, 131-136, 2013
1942013
Study of direct electron transfer and enzyme activity of glucose oxidase on graphene surface
B Liang, X Guo, L Fang, Y Hu, G Yang, Q Zhu, J Wei, X Ye
Electrochemistry Communications 50, 1-5, 2015
1242015
Three-dimensional paper-based microfluidic electrochemical integrated devices (3D-PMED) for wearable electrochemical glucose detection
Q Cao, B Liang, T Tu, J Wei, L Fang, X Ye
RSC advances 9 (10), 5674-5681, 2019
1232019
Fabrication and application of flexible graphene silk composite film electrodes decorated with spiky Pt nanospheres
B Liang, L Fang, Y Hu, G Yang, Q Zhu, X Ye
Nanoscale 6 (8), 4264-4274, 2014
1102014
Antifouling zwitterionic coating via electrochemically mediated atom transfer radical polymerization on enzyme-based glucose sensors for long-time stability in 37 C serum
Y Hu, B Liang, L Fang, G Ma, G Yang, Q Zhu, S Chen, X Ye
Langmuir 32 (45), 11763-11770, 2016
822016
Research on the construction of portable electrochemical sensors for environmental compounds quality monitoring
Q He, B Wang, J Liang, J Liu, B Liang, G Li, Y Long, G Zhang, H Liu
Materials Today Advances 17, 100340, 2023
692023
An integrated and conductive hydrogel-paper patch for simultaneous sensing of Chemical–Electrophysiological signals
T Li, B Liang, Z Ye, L Zhang, S Xu, T Tu, Y Zhang, Y Cai, B Zhang, L Fang, ...
Biosensors and Bioelectronics 198, 113855, 2022
582022
A needle-type glucose biosensor based on PANI nanofibers and PU/E-PU membrane for long-term invasive continuous monitoring
L Fang, B Liang, G Yang, Y Hu, Q Zhu, X Ye
Biosensors and Bioelectronics 97, 196-202, 2017
582017
Design and parametric optimization of thermal management of lithium-ion battery module with reciprocating air-flow
Y Liu, C Ouyang, Q Jiang, B Liang
Journal of central south university 22 (10), 3970-3976, 2015
492015
Study of glucose biosensor lifetime improvement in 37 C serum based on PANI enzyme immobilization and PLGA biodegradable membrane
L Fang, B Liang, G Yang, Y Hu, Q Zhu, X Ye
Biosensors and Bioelectronics 56, 91-96, 2014
482014
One-step modification of nano-polyaniline/glucose oxidase on double-side printed flexible electrode for continuous glucose monitoring: Characterization, cytotoxicity evaluation …
Y Cai, B Liang, S Chen, Q Zhu, T Tu, K Wu, Q Cao, L Fang, X Liang, X Ye
Biosensors and Bioelectronics 165, 112408, 2020
462020
Glucose biosensor based on a platinum electrode modified with rhodium nanoparticles and with glucose oxidase immobilized on gold nanoparticles
X Guo, B Liang, J Jian, Y Zhang, X Ye
Microchimica Acta 181, 519-525, 2014
462014
An integrated paper-based microfluidic device for real-time sweat potassium monitoring
B Liang, Q Cao, X Mao, W Pan, T Tu, L Fang, X Ye
IEEE Sensors Journal 21 (8), 9642-9648, 2020
422020
3D MXene/PEDOT: PSS composite aerogel with a controllable patterning property for highly sensitive wearable physical monitoring and robotic tactile sensing
S Zhang, T Tu, T Li, Y Cai, Z Wang, Y Zhou, D Wang, L Fang, X Ye, ...
ACS Applied Materials & Interfaces 14 (20), 23877-23887, 2022
412022
The fabrication of superlow protein absorption zwitterionic coating by electrochemically mediated atom transfer radical polymerization and its application
Y Hu, G Yang, B Liang, L Fang, G Ma, Q Zhu, S Chen, X Ye
Acta Biomaterialia 13, 142-149, 2015
382015
A smartwatch integrated with a paper‐based microfluidic patch for sweat electrolytes monitoring
Q Cao, B Liang, X Mao, J Wei, T Tu, L Fang, X Ye
Electroanalysis 33 (3), 643-651, 2021
342021
An integrated electrochemical POCT platform for ultrasensitive circRNA detection towards hepatocellular carcinoma diagnosis
B Zhang, M Chen, J Cao, Y Liang, T Tu, J Hu, T Li, Y Cai, S Li, B Liu, J Xu, ...
Biosensors and Bioelectronics 192, 113500, 2021
332021
3D bimetallic Au/Pt nanoflowers decorated needle-type microelectrode for direct in situ monitoring of ATP secreted from living cells
Q Zhu, B Liang, Y Liang, L Ji, Y Cai, K Wu, T Tu, H Ren, B Huang, J Wei, ...
Biosensors and Bioelectronics 153, 112019, 2020
322020
Controllable Patterning of Porous MXene (Ti3C2) by Metal‐Assisted Electro‐Gelation Method
T Tu, B Liang, S Zhang, T Li, B Zhang, S Xu, X Mao, Y Cai, L Fang, X Ye
Advanced Functional Materials 31 (31), 2101374, 2021
312021
Vertically aligned PANI nanorod arrays grown on graphene oxide nanosheets for a high-performance NH 3 gas sensor
J Wei, B Liang, Q Cao, C Mo, Y Zheng, X Ye
RSC advances 7 (53), 33510-33520, 2017
282017
Das System kann den Vorgang jetzt nicht ausführen. Versuchen Sie es später erneut.
Artikel 1–20