Automated seeded lesion segmentation on digital mammograms MA Kupinski, ML Giger IEEE Transactions on medical imaging 17 (4), 510-517, 1998 | 391 | 1998 |
Computerized lesion detection on breast ultrasound K Drukker, ML Giger, K Horsch, MA Kupinski, CJ Vyborny, EB Mendelson Medical physics 29 (7), 1438-1446, 2002 | 287 | 2002 |
Computer-aided diagnosis in mammography ML Giger, Z Huo, MA Kupinski, CJ Vyborny Handbook of medical imaging 2, 915-1004, 2000 | 180 | 2000 |
Ideal-observer computation in medical imaging with use of Markov-chain Monte Carlo techniques MA Kupinski, JW Hoppin, E Clarkson, HH Barrett JOSA A 20 (3), 430-438, 2003 | 176 | 2003 |
Quantitative analysis of acute myocardial infarct in rat hearts with ischemia-reperfusion using a high-resolution stationary SPECT system Z Liu, GA Kastis, GD Stevenson, HH Barrett, LR Furenlid, MA Kupinski, ... Journal of Nuclear Medicine 43 (7), 933-939, 2002 | 168 | 2002 |
Maximum-likelihood estimation with a contracting-grid search algorithm JY Hesterman, L Caucci, MA Kupinski, HH Barrett, LR Furenlid IEEE transactions on nuclear science 57 (3), 1077-1084, 2010 | 153 | 2010 |
Ideal observer approximation using Bayesian classification neural networks MA Kupinski, DC Edwards, ML Giger, CE Metz IEEE transactions on medical imaging 20 (9), 886-899, 2001 | 141 | 2001 |
Method and system for the segmentation and classification of lesions MA Kupinski, ML Giger US Patent 6,138,045, 2000 | 141 | 2000 |
Task-based measures of image quality and their relation to radiation dose and patient risk HH Barrett, KJ Myers, C Hoeschen, MA Kupinski, MP Little Physics in Medicine & Biology 60 (2), R1, 2015 | 140 | 2015 |
Multiobjective genetic optimization of diagnostic classifiers with implications for generating receiver operating characteristic curves MA Kupinski, MA Anastasio IEEE Transactions on Medical Imaging 18 (8), 675-685, 1999 | 130 | 1999 |
Adaptive spect HH Barrett, LR Furenlid, M Freed, JY Hesterman, MA Kupinski, ... IEEE transactions on medical imaging 27 (6), 775-788, 2008 | 115 | 2008 |
Gaussian profile estimation in one dimension N Hagen, M Kupinski, EL Dereniak Applied optics 46 (22), 5374-5383, 2007 | 89 | 2007 |
Maximum likelihood fitting of FROC curves under an initial‐detection‐and‐candidate‐analysis model DC Edwards, MA Kupinski, CE Metz, RM Nishikawa Medical physics 29 (12), 2861-2870, 2002 | 88 | 2002 |
Efficiency of the human observer detecting random signals in random backgrounds S Park, E Clarkson, MA Kupinski, HH Barrett JOSA A 22 (1), 3-16, 2005 | 85 | 2005 |
Ideal observers and optimal ROC hypersurfaces in N-class classification DC Edwards, CE Metz, MA Kupinski IEEE Transactions on Medical Imaging 23 (7), 891-895, 2004 | 84 | 2004 |
Small-animal SPECT imaging MA Kupinski Springer, 2005 | 78 | 2005 |
Feature selection with limited datasets MA Kupinski, ML Giger Medical Physics 26 (10), 2176-2182, 1999 | 77 | 1999 |
The multi‐module, multi‐resolution system: A novel small‐animal SPECT system JY Hesterman, MA Kupinski, LR Furenlid, DW Wilson, HH Barrett Medical physics 34 (3), 987-993, 2007 | 75 | 2007 |
Channelized-ideal observer using Laguerre-Gauss channels in detection tasks involving non-Gaussian distributed lumpy backgrounds and a Gaussian signal S Park, HH Barrett, E Clarkson, MA Kupinski, KJ Myers JOSA A 24 (12), B136-B150, 2007 | 74 | 2007 |
Objective comparison of quantitative imaging modalities without the use of a gold standard JW Hoppin, MA Kupinski, GA Kastis, E Clarkson, HH Barrett IEEE transactions on medical imaging 21 (5), 441-449, 2002 | 69 | 2002 |