Textile electrodes in capacitive signal sensing applications B Babusiak, S Borik, L Balogova Measurement 114, 69-77, 2018 | 49 | 2018 |
Two-electrode ECG for ambulatory monitoring with minimal hardware complexity B Babusiak, S Borik, M Smondrk Sensors 20 (8), 2386, 2020 | 21 | 2020 |
Low energy wireless communication for medical devices B Babusiak, S Borik 2015 38th International Conference on Telecommunications and Signal …, 2015 | 12 | 2015 |
Design of ultra-low-energy temperature and humidity sensor based on nrf24 wireless technology B Babusiak, M Smondrk, S Borik 2019 42nd International Conference on Telecommunications and Signal …, 2019 | 11 | 2019 |
Smart glove to measure a grip force of the workers S Borik, A Kmecova, M Gasova, M Gaso 2019 42nd international conference on telecommunications and signal …, 2019 | 11 | 2019 |
On the spatial phase distribution of cutaneous low-frequency perfusion oscillations S Borik, S Lyra, V Perlitz, M Keller, S Leonhardt, V Blazek Scientific Reports 12 (1), 5997, 2022 | 10 | 2022 |
Photoplethysmography imaging: camera performance evaluation by means of an optoelectronic skin perfusion phantom S Borik, S Lyra, M Paul, CH Antink, S Leonhardt, V Blazek Physiological Measurement 41 (5), 054001, 2020 | 9 | 2020 |
Bio-Amplifier with programmable gain and adjustable leads B Babušiak, Š Borik 2013 36th International Conference on Telecommunications and Signal …, 2013 | 9 | 2013 |
Investigation of pulse wave velocity in arteries S Borik, I Cap 2012 35th International Conference on Telecommunications and Signal …, 2012 | 9 | 2012 |
Implementation of wireless data transfer to photoplethysmographic measurements Š Borik, I Čáp 2012 ELEKTRO, 407-410, 2012 | 9 | 2012 |
Measurement and analysis possibilities of pulse wave signals S Borik, I Cap Advances in Electrical and Electronic Engineering 11 (6), 514-521, 2013 | 7 | 2013 |
Common-mode voltage reduction in capacitive sensing of biosignal using capacitive grounding and DRL electrode T Bednar, B Babusiak, M Labuda, M Smetana, S Borik Sensors 21 (7), 2568, 2021 | 6 | 2021 |
The impact of active electrode guard layer in capacitive measurements of biosignals T Bednar, B Babusiak, M Smondrk, I Cap, S Borik Measurement 171, 108740, 2021 | 6 | 2021 |
Smart sheet design for electrocardiogram measurement B Babusiak, S Borik, M Smondrk, L Janousek Information Technology in Biomedicine, 507-517, 2019 | 5 | 2019 |
Bluetooth communication for battery powered medical devices B Babusiak, S Borik Journal of Electrical Engineering 67 (1), 65, 2016 | 5 | 2016 |
Hardware design of ECG data logger B Babusiak, M Gala, S Borik 2014 ELEKTRO, 514-517, 2014 | 5 | 2014 |
Bio-amplifier with programmable gain and adjustable leads for basic measurement of bioelectric signals B Babusiak, S Borik, M Gala Information Technologies in Biomedicine, Volume 4, 249-260, 2014 | 5 | 2014 |
Design of measurement device for impedance cardiography M Snajdarova, S Borik, I Cap 2017 18th International Conference on Computational Problems of Electrical …, 2017 | 4 | 2017 |
Biofeedback-Smart Modality Fusion for Clinical, Home and Outdoor Health Monitoring B Venema, N Blanik, V Perlitz, S Laffar, HG Ortlepp, S Borik, JP Jansen, ... Biomedical Engineering-Biomedizinische Technik 59, S116-S120, 2014 | 4 | 2014 |
Nondestructive evaluation of arterial system properties using electromechanical analogies and light based diagnostic methods S Borik, I Cap Studies in Applied Electromagnetics and Mechanics 39, 85-92, 2014 | 4 | 2014 |